CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded JCR Q4 Özgün Makale Scopus
End-user verification results of two serum separator tubes for clinical chemistry analytes according to CLSI GP34-A and CLSI GP41-A6
Scandinavian Journal of Clinical and Laboratory Investigation 2024 Cilt 84 Sayı 3
Scopus Eşleşmesi Bulundu
1
Atıf
84
Cilt
183-192
Sayfa
Özet
Tube manufacturers use different composition of gels and blood clot activator formulations in serum tube production. Our aim was to investigate the within-tube (repeatability) and between-tube variation, concordance between comparison results of BD and VacuSEL tubes. Blood samples were collected from control subjects (n = 20) and patients (n = 30) in accordance with the CLSI GP41-A6 and CLSI GP34-A guidelines. Twenty-three clinical chemistry parameters were analysed via Roche Cobas C702 Chemistry Analyzer on T0 (0 hour) and T24 (24 hour). Mean differences % were compared with Wilcoxon matched pair test. Clinical significance was evaluated based on desirable bias according to total allowable error (TEa). VacuSEL tubes demonstrated acceptable performance for the results of 20 parameters with regards to desirable bias % limits. Lactate dehydrogenase (LD) [mean difference % (%95 confidence intervals (CI) values of BD and VacuSEL tubes at T0 [6.41% (4.80–8.01%)]; sodium (Na) and total protein (TP) at T24 [-0.27% (-0.46 to −0.07%) and −1.39% (-1.87 to −0.91), respectively] were over the desirable bias limits (LD: 4.3%, Na: 0.23% and TP: 1.36%, respectively) but not exceeding total biological variation CV % [Na: 0.5 (0.0–1.0) % and TP: 2.6 (2.3–2.7) %). %95 confidence intervals (CI) of T0 LD values overlap with within-subject biological variation % (CI) limits (LD: 5.2 (4.9–5.4) %). The differences between two tubes were not medically significant and necessarily conclusive. VacuSEL serum tubes presented comparable performance with BD serum tubes.
Web of Science Eşleşmesi Bulundu
1
WoS Atıf
84
Cilt
Article
Belge Türü
Kaynak: SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION · s. 183-192
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 1.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2024 yılı verileri
Scandinavian Journal of Clinical and Laboratory Investigation
Q3
SJR Quartile
0,471
SJR Skoru
76
H-Index
Kategoriler: Clinical Biochemistry (Q3) · Medicine (miscellaneous) (Q3)
Alanlar: Biochemistry, Genetics and Molecular Biology · Medicine
Ülke: United Kingdom · Informa Healthcare
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

WoS | Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.

Makale Bilgileri

Dergi Scandinavian Journal of Clinical and Laboratory Investigation
ISSN 0036-5513
Yıl 2024 / 5. ay
Cilt / Sayı 84 / 3
Sayfalar 5 – 16
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
JCR Quartile Q4
Teşvik Puanı 0,50 · YÖKSİS Akademik Teşvik
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 9 kişi
Erişim Türü Basılı+Elektronik
Alan Sağlık Bilimleri Temel Alanı Tıbbi Biyokimya

YÖKSİS Yazar Kaydı

Yazar Adı ABUŞOĞLU SEDAT,ECER BÜŞRA,GÜVEN HALİL,yorulmaz ahmet emre,SERDAR MUHİTTİN ABDULKADİR,ÜNLÜ ALİ,AKYÜREK FİKRET,ÖZTÜRK BAHADIR,ABUŞOĞLU GÜLSÜM
YÖKSİS ID 8274040

Metrikler

Scopus Atıf 1
Havuz Atıfları 0
JCR Quartile Q4
Teşvik Puanı 0,50
Yazar Sayısı 9