Özet
Tube manufacturers use different composition of gels and blood clot activator formulations in serum tube production. Our aim was to investigate the within-tube (repeatability) and between-tube variation, concordance between comparison results of BD and VacuSEL tubes. Blood samples were collected from control subjects (n = 20) and patients (n = 30) in accordance with the CLSI GP41-A6 and CLSI GP34-A guidelines. Twenty-three clinical chemistry parameters were analysed via Roche Cobas C702 Chemistry Analyzer on T0 (0 hour) and T24 (24 hour). Mean differences % were compared with Wilcoxon matched pair test. Clinical significance was evaluated based on desirable bias according to total allowable error (TEa). VacuSEL tubes demonstrated acceptable performance for the results of 20 parameters with regards to desirable bias % limits. Lactate dehydrogenase (LD) [mean difference % (%95 confidence intervals (CI) values of BD and VacuSEL tubes at T0 [6.41% (4.80–8.01%)]; sodium (Na) and total protein (TP) at T24 [-0.27% (-0.46 to −0.07%) and −1.39% (-1.87 to −0.91), respectively] were over the desirable bias limits (LD: 4.3%, Na: 0.23% and TP: 1.36%, respectively) but not exceeding total biological variation CV % [Na: 0.5 (0.0–1.0) % and TP: 2.6 (2.3–2.7) %). %95 confidence intervals (CI) of T0 LD values overlap with within-subject biological variation % (CI) limits (LD: 5.2 (4.9–5.4) %). The differences between two tubes were not medically significant and necessarily conclusive. VacuSEL serum tubes presented comparable performance with BD serum tubes.
1 atıf Ocak 2024 DOI
YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
End-user verification results of two serum separator tubes for clinical chemistry analytes according to CLSI GP34-A and CLSI GP41-A6
Scandinavian Journal of Clinical and Laboratory Investigation · 2024 SCI-Expanded
Prof. Dr. ALİ ÜNLÜ →
End-user verification results of two serum separator tubes for clinical chemistry analytes according to CLSI GP34-A and CLSI GP41-A6
Scandinavian Journal of Clinical and Laboratory Investigation · 2024 SCI-Expanded
Prof. Dr. ALİ ÜNLÜ →
End-user verification results of two serum separator tubes for clinical chemistry analytes according to CLSI GP34-A and CLSI GP41-A6
Scandinavian Journal of Clinical and Laboratory Investigation · 2024 SCI-Expanded
Prof. Dr. ALİ ÜNLÜ →
End-user verification results of two serum separator tubes for clinical chemistry analytes according to CLSI GP34-A and CLSI GP41-A6
Scandinavian Journal of Clinical and Laboratory Investigation · 2024 SCI-Expanded
Prof. Dr. ALİ ÜNLÜ →
End-user verification results of two serum separator tubes for clinical chemistry analytes according to CLSI GP34-A and CLSI GP41-A6
Scandinavian Journal of Clinical and Laboratory Investigation · 2024 SCI-Expanded
Prof. Dr. BAHADIR ÖZTÜRK →
End-user verification results of two serum separator tubes for clinical chemistry analytes according to CLSI GP34-A and CLSI GP41-A6
Scandinavian Journal of Clinical and Laboratory Investigation · 2024 SCI-Expanded
Prof. Dr. SEDAT ABUŞOĞLU →
End-user verification results of two serum separator tubes for clinical chemistry analytes according to CLSI GP34-A and CLSI GP41-A6
Scandinavian Journal of Clinical and Laboratory Investigation · 2024 SCI-Expanded
Doç. Dr. GÜLSÜM ABUŞOĞLU →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 7 kaydı bulundu.
Investigation of the relationship between trimethylamine N-oxide, CD36, and CD38 levels in individuals with a high triglyceride/HDL-cholesterol ratio
2026 ISSN: 0036-5513 SCI-Expanded Q3
Prof. Dr. BAHADIR ÖZTÜRK →
Kynurenine pathway activation in ectopic pregnancy: diagnostic value of 3-hydroxykynurenine and 3-hydroxyanthranilic acid; a prospective study
2026 ISSN: 0036-5513 SCI
Prof. Dr. HÜSAMETTİN VATANSEV →
End-user verification results of two serum separator tubes for clinical chemistry analytes according to CLSI GP34-A and CLSI GP41-A6
2024 ISSN: 0036-5513 SCI-Expanded Q4
Prof. Dr. ALİ ÜNLÜ →
End-user verification results of two serum separator tubes for clinical chemistry analytes according to CLSI GP34-A and CLSI GP41-A6
2024 ISSN: 0036-5513 SCI-Expanded Q3
Doç. Dr. GÜLSÜM ABUŞOĞLU →
End-user verification results of two serum separator tubes for clinical chemistry analytes according to CLSI GP34-A and CLSI GP41-A6
2024 ISSN: 0036-5513 SCI-Expanded Q3
Prof. Dr. ALİ ÜNLÜ →
End-user verification results of two serum separator tubes for clinical chemistry analytes according to CLSI GP34-A and CLSI GP41-A6
2024 ISSN: 0036-5513 SCI-Expanded Q4
Prof. Dr. ALİ ÜNLÜ →
Relationship of kynurenine pathway metabolites and indoleamine 2,3-dioxygenase with atherosclerosis: data obtained from pericardial fluid in coronary artery bypass surgery
2025 ISSN: 0036-5513 SCI-Expanded Q3
Prof. Dr. ALİ ÜNLÜ →

Makale Bilgileri

Toplam Atıf 1 atıf · Scopus
ISSN00365513
Yayın TarihiOcak 2024
Cilt / Sayfa84 · 183-192

Kurumlar

Acıbadem Mehmet Ali Aydınlar Üniversitesi
Istanbul Turkey
Selçuk Tip Fakültesi
Konya Turkey
Selçuk Üniversitesi
Selçuklu Turkey

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 1.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi (ISSN Eşleşmesi)
Scandinavian Journal of Clinical and Laboratory Investigation
Q3
SJR Skoru0,493
H-Index78
YayıncıTaylor and Francis Ltd.
ÜlkeUnited Kingdom
Clinical Biochemistry (Q3)
Medicine (miscellaneous) (Q3)
Dergi sayfasına git

Metrikler

1
Atıf

Sistemimizdeki Yazarlar