Evaluation of the effect of fasting on intraocular pressure, anterior segment parameters and density of crystalline lens and cornea
International Ophthalmology 2020 Cilt 40
Scopus Eşleşmesi Bulundu
9
Atıf
40
Cilt
2987-2994
Sayfa
Özet
Purpose: To evaluate the effect of fasting on anterior chamber depth, anterior chamber volume and corneal and lens density by Scheimpflug technology and to measure intraocular pressure changes. Methods: Totals of 50 healthy fasting individuals in Ramadan (study group) and 50 healthy non-fasting subjects (control group) were included. Central corneal thickness (CCT), anterior chamber depth (ACD), anterior chamber volume (ACV), corneal density (CD) and lens density (LD) were evaluated with Scheimpflug technology. Intraocular pressure (IOP) was measured with applanation tonometry. Both eyes of each participant were examined and also compared. Results: Comparison of groups: There was a statistically significant difference between CD, ACD, ACV and IOP (respectively, right/left eye: fasting: CD: 12.81 ± 0.76/12.73 ± 0.73; ACD: 2.92 ± 0.37 mm/2.93 ± 0.37 mm; ACV: 168.3 ± 41.82 mm3/183.34 ± 32.46 mm3; IOP: 13.80 ± 1.22 mmHg/14.88 ± 2.73 mmHg; non-fasting: CD: 13.28 ± 1.01/13.17 ± 0.77; ACD: 3.06 ± 0.31 mm/3.07 ± 0.31 mm; ACV: 167.46 ± 42.92 mm3/180.68 ± 31.45 mm3; IOP: 13.60 ± 1.65 mmHg/14.74 ± 2.93 mmHg) values on the right side (p < 0.01, p = 0.03, p = 0.04, p = 0.01, respectively). Although there was a statistically significant difference between the ACV, CD and IOP values on the left side (p < 0.01, p = 0.03, p = 0.01, respectively), no statistical significance was found for the ACV value on the left side (p = 0.08). Conclusion: The results demonstrated that, while fasting did not lead to any change in LD and CCT, it caused a small decrease in ACD and ACV, and a significant decrease in CD and IOP values. Scheimpflug technology seems to be a valuable tool for the evaluation of anterior segment changes in patients who are fasting.
Web of Science Eşleşmesi Bulundu
8
WoS Atıf
40
Cilt
Article
Belge Türü
Kaynak: INTERNATIONAL OPHTHALMOLOGY · s. 2987-2994
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 9.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.

Anahtar Kelimeler

WoS | Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.

Makale Bilgileri

Dergi International Ophthalmology
ISSN 0165-5701","1573-2630
Yıl 2020 / 1. ay
Cilt / Sayı 40
Sayfalar 2987 – 2994
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
Teşvik Puanı 27,00 · YÖKSİS Akademik Teşvik
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 3 kişi
Erişim Türü Elektronik
Alan Sağlık Bilimleri Temel Alanı Göz Hastalıkları

YÖKSİS Yazar Kaydı

Yazar Adı BEYOĞLU ABDULLAH, KARAKÜÇÜK YALÇIN, ÇÖMEZ AYŞEGÜL
YÖKSİS ID 5677355

Metrikler

Scopus Atıf 9
Havuz Atıfları 0
Teşvik Puanı 27,00
Yazar Sayısı 3