Scopus
YÖKSİS DOI Eşleşti
SJR Q2
Evaluation of the effect of fasting on intraocular pressure, anterior segment parameters and density of crystalline lens and cornea
International Ophthalmology · Kasım 2020
Özet
Purpose: To evaluate the effect of fasting on anterior chamber depth, anterior chamber volume and corneal and lens density by Scheimpflug technology and to measure intraocular pressure changes. Methods: Totals of 50 healthy fasting individuals in Ramadan (study group) and 50 healthy non-fasting subjects (control group) were included. Central corneal thickness (CCT), anterior chamber depth (ACD), anterior chamber volume (ACV), corneal density (CD) and lens density (LD) were evaluated with Scheimpflug technology. Intraocular pressure (IOP) was measured with applanation tonometry. Both eyes of each participant were examined and also compared. Results: Comparison of groups: There was a statistically significant difference between CD, ACD, ACV and IOP (respectively, right/left eye: fasting: CD: 12.81 ± 0.76/12.73 ± 0.73; ACD: 2.92 ± 0.37 mm/2.93 ± 0.37 mm; ACV: 168.3 ± 41.82 mm3/183.34 ± 32.46 mm3; IOP: 13.80 ± 1.22 mmHg/14.88 ± 2.73 mmHg; non-fasting: CD: 13.28 ± 1.01/13.17 ± 0.77; ACD: 3.06 ± 0.31 mm/3.07 ± 0.31 mm; ACV: 167.46 ± 42.92 mm3/180.68 ± 31.45 mm3; IOP: 13.60 ± 1.65 mmHg/14.74 ± 2.93 mmHg) values on the right side (p < 0.01, p = 0.03, p = 0.04, p = 0.01, respectively). Although there was a statistically significant difference between the ACV, CD and IOP values on the left side (p < 0.01, p = 0.03, p = 0.01, respectively), no statistical significance was found for the ACV value on the left side (p = 0.08). Conclusion: The results demonstrated that, while fasting did not lead to any change in LD and CCT, it caused a small decrease in ACD and ACV, and a significant decrease in CD and IOP values. Scheimpflug technology seems to be a valuable tool for the evaluation of anterior segment changes in patients who are fasting.
YÖKSİS Kayıtları
Evaluation of the effect of fasting on intraocular pressure, anterior segment parameters and density of crystalline lens and cornea
International Ophthalmology · 2020 SCI-Expanded
Doç. Dr. ABDULLAH BEYOĞLU →
Evaluation of the Effect of Fasting on Intraocular Pressure, Anterior Segment Parameters and Density of Cristalline Lens and Cornea
INTERNATIONAL OPHTHALMOLOGY · 2020 SCI-Expanded
Doç. Dr. ABDULLAH BEYOĞLU →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 5 kaydı bulundu.
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 5 kaydı bulundu.
Therapeutic effects of Chelidonium majus on ocular surface ınflammation and tear film homeostasis in a benzalkonium chloride-ınduced rat model of dry eye disease
2026 ISSN: 0165-5701 SCI
Prof. Dr. ZELİHA ESİN ÇELİK →
Quantitative assessment of the effect of acute anaerobic exercise on macular perfusion via swept-source optical coherence tomography angiography in young football players
2020 ISSN: 0165-5701 SCI-Expanded
Arş. Gör. TUĞBA SEZER →
Quantitative assessment of the effect of acute anaerobic exercise on macular perfusion via swept-source optical coherence tomography angiography in young football players
2020 ISSN: 0165-5701 SCI-Expanded
Prof. Dr. NİLSEL OKUDAN →
Morphometric and morphological evaluation of the optic canal in three different parts in MDCT images
2023 ISSN: 0165-5701 SCI-Expanded
Prof. Dr. AHMET KAĞAN KARABULUT →
Retinal nerve fiber layer analysis and interpretation of GDx parameters in patients with tilted disc syndrome
2001 ISSN: 01655701 SCI
Prof. Dr. BANU BOZKURT →
Makale Bilgileri
Toplam Atıf
9 atıf
· Scopus
ISSN01655701
Yayın TarihiKasım 2020
Cilt / Sayfa40 · 2987-2994
Scopus ID2-s2.0-85087393715
Kurumlar
Kahramanmaras Sütçü Imam Üniversitesi
Kahramanmaras Turkey
Selçuk Üniversitesi
Selçuklu Turkey
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 9.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi (ISSN Eşleşmesi)
International Ophthalmology
Q2
SJR Skoru0,643
H-Index61
YayıncıSpringer Science and Business Media B.V.
ÜlkeNetherlands
Ophthalmology (Q2)
Metrikler
9
Atıf