CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded Özgün Makale Scopus
Density of crystalline lens and cornea in different trimesters of pregnancy
Contact Lens and Anterior Eye 2019 Cilt 42 Sayı 3
Scopus Eşleşmesi Bulundu
7
Atıf
42
Cilt
283-288
Sayfa
Özet
Purpose: To evaluate topographic measurements of the anterior segment and densitometric measurements of the cornea and lens by Pentacam HR in different trimesters of pregnancy. Methods: This prospective study included 150 healthy pregnant women in their first, second, or third trimester (Groups 1, 2 and 3, respectively) and 54 non-pregnant healthy women (Group 0). Topographic measurements, including central corneal thickness (CCT), corneal volume (CV), anterior chamber depth (ACD), corneal densitometry (CD) and lens densitometry (LD), were done with the Pentacam HR (Oculus, Wetzlar, Germany). The measurement results of the healthy pregnant women and non-pregnant healthy women were compared. Results: CD values were found in Group 1 to be 13.19, in Group 2 to be 13.16, in Group 3 to be 13.17 and in Group 0 to be 13.22 (p = 0.811). The mean Group 1, Group 2, Group 3 and Group 0 LD-horizontal was 5.40 ± 0.5, 5.47 ± 0.38, 5.53 ± 0.44, 5.36 ± 0.43, respectively. The mean Group 1, Group 2, Group 3 and Group 0 LD-vertical was 5.6 ± 0.43, 5.66 ± 0.32, 5.71 ± 0.40 and 5.5 ± 0.44, respectively. Area LD values were higher in the advanced trimester period, and the only statistically significant difference was between Group 3 and Group 0 (p = 0.025). The difference between three-dimensional (3D) and peak LD values was not statistically significant between the groups (p = 0.89 and p = 0.91, respectively). Discussion: The Pentacam HR seems to be an important option for the evaluation of LD, CD and topographic measurements of the anterior segment in pregnancy. In the present study, CD and LD, including LD-horizontal, LD-vertical, peak and 3D values, were not significantly different between pregnant women and non-pregnant women.
Web of Science Eşleşmesi Bulundu
6
WoS Atıf
42
Cilt
Article
Belge Türü
Kaynak: CONTACT LENS & ANTERIOR EYE · s. 283-288
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 7.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2019 yılı verileri
Contact Lens and Anterior Eye
Q1
SJR Quartile
0,915
SJR Skoru
69
H-Index
Kategoriler: Medicine (miscellaneous) (Q1) · Optometry (Q1) · Ophthalmology (Q2)
Alanlar: Health Professions · Medicine
Ülke: Netherlands · Elsevier B.V.
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

WoS | Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.

Makale Bilgileri

Dergi Contact Lens and Anterior Eye
ISSN 1367-0484
Yıl 2019 / 6. ay
Cilt / Sayı 42 / 3
Sayfalar 283 – 288
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
Teşvik Puanı 2,40 · YÖKSİS Akademik Teşvik
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 6 kişi
Erişim Türü Elektronik
Alan Sağlık Bilimleri Temel Alanı- Göz Hastalıkları

YÖKSİS Yazar Kaydı

Yazar Adı KARAKÜÇÜK YALÇIN, ALTINKAYNAK HASAN, KARAKÜÇÜK SELİM, BEYOĞLU ABDULLAH, ÇÖMEZ AYŞEGÜL, DEMİR MUSTAFA
YÖKSİS ID 4462815

Metrikler

Scopus Atıf 7
Havuz Atıfları 0
Teşvik Puanı 2,40
Yazar Sayısı 6