CANLI
Yükleniyor Veriler getiriliyor…
/ Makaleler / Scopus Detay
Scopus YÖKSİS DOI Eşleşti SJR Q1

Density of crystalline lens and cornea in different trimesters of pregnancy

Contact Lens and Anterior Eye · Haziran 2019

Özet
Purpose: To evaluate topographic measurements of the anterior segment and densitometric measurements of the cornea and lens by Pentacam HR in different trimesters of pregnancy. Methods: This prospective study included 150 healthy pregnant women in their first, second, or third trimester (Groups 1, 2 and 3, respectively) and 54 non-pregnant healthy women (Group 0). Topographic measurements, including central corneal thickness (CCT), corneal volume (CV), anterior chamber depth (ACD), corneal densitometry (CD) and lens densitometry (LD), were done with the Pentacam HR (Oculus, Wetzlar, Germany). The measurement results of the healthy pregnant women and non-pregnant healthy women were compared. Results: CD values were found in Group 1 to be 13.19, in Group 2 to be 13.16, in Group 3 to be 13.17 and in Group 0 to be 13.22 (p = 0.811). The mean Group 1, Group 2, Group 3 and Group 0 LD-horizontal was 5.40 ± 0.5, 5.47 ± 0.38, 5.53 ± 0.44, 5.36 ± 0.43, respectively. The mean Group 1, Group 2, Group 3 and Group 0 LD-vertical was 5.6 ± 0.43, 5.66 ± 0.32, 5.71 ± 0.40 and 5.5 ± 0.44, respectively. Area LD values were higher in the advanced trimester period, and the only statistically significant difference was between Group 3 and Group 0 (p = 0.025). The difference between three-dimensional (3D) and peak LD values was not statistically significant between the groups (p = 0.89 and p = 0.91, respectively). Discussion: The Pentacam HR seems to be an important option for the evaluation of LD, CD and topographic measurements of the anterior segment in pregnancy. In the present study, CD and LD, including LD-horizontal, LD-vertical, peak and 3D values, were not significantly different between pregnant women and non-pregnant women.
7 atıf Haziran 2019 DOI
YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
Density of crystalline lens and cornea in different trimesters of pregnancy
Contact Lens and Anterior Eye · 2019 SCI-Expanded
Doç. Dr. ABDULLAH BEYOĞLU →
Density of crystalline lens and cornea in different trimesters of pregnancy
Contact Lens and Anterior Eye · 2018 SCI-Expanded
Doç. Dr. ABDULLAH BEYOĞLU →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 4 kaydı bulundu.
Density of crystalline lens and cornea in different trimesters of pregnancy
2019 ISSN: 1367-0484 SCI-Expanded
Doç. Dr. ABDULLAH BEYOĞLU →
Associations with meibomian gland loss in soft and rigid contact lens wearers
2022 ISSN: 1367-0484 SCI-Expanded Q2
Prof. Dr. BANU BOZKURT →
Associations with meibomian gland loss in soft and rigid contact lens wearers
2021 ISSN: 1367-0484 SCI-Expanded Q2
Prof. Dr. BANU BOZKURT →
Associations with meibomian gland loss in soft and rigid contact lens wearers
2022 ISSN: 1367-0484 SCI-Expanded Q2
Prof. Dr. BANU BOZKURT →

Makale Bilgileri

Toplam Atıf 7 atıf · Scopus
ISSN13670484
Yayın TarihiHaziran 2019
Cilt / Sayfa42 · 283-288

Kurumlar

Kahramanmaras Sütçü Imam Üniversitesi
Kahramanmaras Turkey
Midyat State Hospital
Mardin Turkey
Selçuk Üniversitesi
Selçuklu Turkey
VKV Amerikan Hastanesi
Istanbul Turkey

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 7.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi (ISSN Eşleşmesi)
Contact Lens and Anterior Eye
Q1
SJR Skoru1,551
H-Index73
YayıncıElsevier B.V.
ÜlkeNetherlands
Medicine (miscellaneous) (Q1)
Ophthalmology (Q1)
Optometry (Q1)
Dergi sayfasına git

Metrikler

7
Atıf

Sistemimizdeki Yazarlar