Objective: The aim of the study was to evaluate the diagnostic accuracy and effective radiation dose (ERD) of high pitch dual source multidetector computed tomography (MDCT) for coronary artery bypass graft (CABG) patency. Materials and methods: Fourty-five patients who underwent 128 × 2‑slice MDCT angiography with a prospective electrocardiogram-triggering, low-dose, high pitch, dual source, flash spiral acquisition mode after CABG surgery were included in the study. The interobserver agreement of the image quality was evaluated with Cohen κ value. The image quality was compared to the heart rates (HRs) using Mann–Whitney U test and to the graft segments using χ 2 test. The findings for the CABG patency on MDCT were compared to those determined on catheter coronary angiography. Dose-length product (DLP) and ERD were compared to the gender, HRs, and body mass index (BMI) of the patients using Kruskall Wallis and Mann–Whitney U tests. Results: A total of 110 grafts and 330 vessel segments were evaluated with a good interobserver agreement (κ = 0.80). The image quality was better in proximal and middle graft segments (p < 0.05), as well as in the patients with low HRs (p < 0.05). High pitch MDCT had the following sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy for evaluation of graft patency: 92.8, 99.3, 92.8, 99.3 and 98.8 %, respectively. ERD was correlated to the HRs and BMI. Conclusions: High pitch 128 × 2‑slice dual source CT angiography is a noninvasive imaging modality, and it can be safely and effectively used in evaluation of CABG patency with lower radiation dose.
Web of Science Eşleşmesi Bulundu
5
WoS Atıf
128
Cilt
Article
Belge Türü
Kaynak: WIENER KLINISCHE WOCHENSCHRIFT
· s. 488-494
Anahtar Kelimeler (WoS)
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 7.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi
Otomatik ISSN Eşleştirmesi
2016 yılı verileri
Wiener Klinische Wochenschrift
Q3
SJR Quartile
0,354
SJR Skoru
65
H-Index
Kategoriler: Medicine (miscellaneous) (Q3)
Alanlar: Medicine
Ülke: Austria
· Springer
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir.
Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.
Anahtar Kelimeler
Coronary artery bypass graft
Dual source
High pitch
Multidetector computed tomography
Radiation dose
WoS |
Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.
Makale Bilgileri
Dergi
Wiener klinische Wochenschrift
ISSN
0043-5325
Yıl
2016
/ 7. ay
Cilt / Sayı
128
/ 13-14
Sayfalar
488 – 494
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SCI
Teşvik Puanı
12,00
· YÖKSİS Akademik Teşvik
Yayın Dili
İngilizce
Kapsam
Uluslararası
Toplam Yazar
8 kişi
Erişim Türü
Basılı+Elektronik
Alan
Sağlık Bilimleri Temel Alanı-
Radyoloji
YÖKSİS Yazar Kaydı
Yazar Adı
KOPLAY MUSTAFA,GÜNEYLİ SERKAN,AKBAYRAK HAKAN,DEMİR KENAN,SİVRİ MESUT,AVCI AHMET,ERDOĞAN HASAN,PAKSOY YAHYA
YÖKSİS ID
2164369