Scopus
YÖKSİS DOI Eşleşti
SJR Q2
Diagnostic accuracy and effective radiation dose of high pitch dual source multidetector computed tomography in evaluation of coronary artery bypass graft patency
Wiener Klinische Wochenschrift · Temmuz 2016
Özet
Objective: The aim of the study was to evaluate the diagnostic accuracy and effective radiation dose (ERD) of high pitch dual source multidetector computed tomography (MDCT) for coronary artery bypass graft (CABG) patency. Materials and methods: Fourty-five patients who underwent 128 × 2‑slice MDCT angiography with a prospective electrocardiogram-triggering, low-dose, high pitch, dual source, flash spiral acquisition mode after CABG surgery were included in the study. The interobserver agreement of the image quality was evaluated with Cohen κ value. The image quality was compared to the heart rates (HRs) using Mann–Whitney U test and to the graft segments using χ 2 test. The findings for the CABG patency on MDCT were compared to those determined on catheter coronary angiography. Dose-length product (DLP) and ERD were compared to the gender, HRs, and body mass index (BMI) of the patients using Kruskall Wallis and Mann–Whitney U tests. Results: A total of 110 grafts and 330 vessel segments were evaluated with a good interobserver agreement (κ = 0.80). The image quality was better in proximal and middle graft segments (p < 0.05), as well as in the patients with low HRs (p < 0.05). High pitch MDCT had the following sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy for evaluation of graft patency: 92.8, 99.3, 92.8, 99.3 and 98.8 %, respectively. ERD was correlated to the HRs and BMI. Conclusions: High pitch 128 × 2‑slice dual source CT angiography is a noninvasive imaging modality, and it can be safely and effectively used in evaluation of CABG patency with lower radiation dose.
YÖKSİS Kayıtları
Diagnostic accuracy and effective radiation dose of high pitch dual source multidetector computed tomography in evaluation of coronary artery bypass graft patency
Wiener klinische Wochenschrift · 2016 SCI-Expanded
Dr. Öğr. Üyesi HAKAN AKBAYRAK →
Diagnostic accuracy and effective radiation dose of high pitch dual source multidetector computed tomography in evaluation of coronary artery bypass graft patency
Wiener klinische Wochenschrift · 2016 SCI
Prof. Dr. MUSTAFA KOPLAY →
Diagnostic accuracy and effective radiation dose of high pitch dual source multidetector computed tomography in evaluation of coronary artery bypass graft patency
Wiener klinische Wochenschrift · 2016 SCI-Expanded
Prof. Dr. KENAN DEMİR →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 11 kaydı bulundu.
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 11 kaydı bulundu.
Effects of body mass index mesenteric and abdominal subcutaneous adipose tissue on the spinopelvic parameters
2015 ISSN: 0043-5325 SCI-Expanded
Prof. Dr. MUSTAFA KOPLAY →
Effects of body mass index mesenteric and abdominal subcutaneous adipose tissue on the spinopelvic parameters
2015 ISSN: 0043-5325 SSCI
Prof. Dr. ALAADDİN NAYMAN →
Effects of body mass index mesenteric and abdominal subcutaneous adipose tissue on the spinopelvic parameters
2015 ISSN: 0043-5325 SCI-Expanded
Prof. Dr. MUSTAFA KOPLAY →
Magnetic resonance imaging findings of absent pulmonary valve syndrome associated with tetralogy of fallot
2011 ISSN: 0043-5325 SCI-Expanded
Prof. Dr. MUSTAFA KOPLAY →
Assessment of smoking for low bone mineral density in postmenopausal Turkish women
2016 ISSN: 0043-5325 SCI
Prof. Dr. MEHMET KULHAN →
Diagnostic accuracy and effective radiation dose of high pitch dual source multidetector computed tomography in evaluation of coronary artery bypass graft patency
2016 ISSN: 0043-5325 SCI
Prof. Dr. MUSTAFA KOPLAY →
Diagnostic accuracy and effective radiation dose of high pitch dual source multidetector computed tomography in evaluation of coronary artery bypass graft patency
2016 ISSN: 0043-5325 SCI-Expanded Q3
Dr. Öğr. Üyesi HAKAN AKBAYRAK →
Diagnostic accuracy and effective radiation dose of high pitch dual source multidetector computed tomography in evaluation of coronary artery bypass graft patency
2016 ISSN: 0043-5325 SCI-Expanded
Prof. Dr. KENAN DEMİR →
Effects of body mass index, mesenteric and abdominal subcutaneous adipose tissue on the spinopelvic parameters
2015 ISSN: 0043-5325 SCI
Doç. Dr. EMİNE UYSAL →
Magnetic resonance imaging findings of absent pulmonary valve syndrome associated with tetralogy of fallot
2011 ISSN: 0043-5325 SCI
Doç. Dr. EMİNE UYSAL →
Psychometric properties of the Turkish version of the fear avoidance components scale in patients with chronic pain related to musculoskeletal disorders
2023 ISSN: 0043-5325 SCI-Expanded
Prof. Dr. ZÜBEYİR SARI →
Makale Bilgileri
Toplam Atıf
7 atıf
· Scopus
ISSN00435325
Yayın TarihiTemmuz 2016
Cilt / Sayfa128 · 488-494
Scopus ID2-s2.0-84976313529
Kurumlar
Selçuk Üniversitesi
Selçuklu Turkey
Zonguldak Bulent Ecevit University
Zonguldak Turkey
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 7.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi (ISSN Eşleşmesi)
Wiener Klinische Wochenschrift
Q2
SJR Skoru0,688
H-Index69
YayıncıSpringer
ÜlkeAustria
Medicine (miscellaneous) (Q2)
Metrikler
7
Atıf