CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded Özgün Makale Scopus
Comparison of 21 g and 27 g needles for the sample adequacy in the aspiration biopsy of the thyroid nodules
Diagnostic and Interventional Radiology 2012 Cilt 18 Sayı 1
Scopus Eşleşmesi Bulundu
25
Atıf
18
Cilt
102-105
Sayfa
Özet
PURPOSE: To compare 21 and 27 gauge (G) needles used for fine-needle aspiration (FNA) of thyroid nodules to obtain better specimens for adequacy and cytological diagnosis. MATERIALS AND METHODS: One hundred patients with thyroid nodules (100 nodules) were included in this study. Each nodule was aspirated with both 27 G and 21 G needles. The obtained aspirates were classified as adequate and inadequate by two separate cytopathologists. The results were analyzed by appropriate statistical methods. RESULTS: There was no statistically significant difference between 21 G and 27 G needles in terms of adequacy, according to each pathologist (P > 0.05). After pathological evaluation with consensus, the adequacy prevalence was the same (84%) for both needle types in all study populations (P > 0.05). According to the ultrasound characteristics of nodules, the prevalence of inadequate samples in patients with hypoechoic or heterogeneous nodules was significantly higher compared with the prevalence of inadequate samples in patients with isoechoic or hyperechoic nodules for both types of needles (P < 0.05). However, according to the size of the needles, there was no significant difference between hypoechoic and heterogeneous nodules or between isoechoic and hyperechoic nodules with regard to the ability to yield adequate samples (P > 0.05). CONCLUSION: The results of our study showed that FNA with 27 G needles can aspirate adequate material for cytopathological diagnosis. The probability of inadequate sample aspiration of hypoechoic and heterogeneous nodules is higher than that for other nodule types. © Turkish Society of Radiology 2012.
Web of Science Eşleşmesi Bulundu
28
WoS Atıf
18
Cilt
Article
Belge Türü
Kaynak: DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY · s. 102-105
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 25.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2012 yılı verileri
Diagnostic and Interventional Radiology
Q2
SJR Quartile
0,500
SJR Skoru
57
H-Index
🔓
Açık Erişim
Kategoriler: Cardiology and Cardiovascular Medicine (Q2) · Radiology, Nuclear Medicine and Imaging (Q2)
Alanlar: Medicine
Ülke: Turkey · Turkish Society of Radiology
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

WoS | Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.

Makale Bilgileri

Dergi Diagnostic and Interventional Radiology
ISSN 1305-3825
Yıl 2012 / 1. ay
Cilt / Sayı 18 / 1
Sayfalar 102 – 105
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 7 kişi
Erişim Türü Elektronik
Alan Sağlık Bilimleri Temel Alanı- Tıbbi Patoloji

YÖKSİS Yazar Kaydı

Yazar Adı GÜMÜŞ MEHMET,Cay n,Algin O,Ipek A,ERSOY REYHAN,belenli o,UĞRAŞ NEVZAT SERDAR
YÖKSİS ID 1814700

Metrikler

Scopus Atıf 25
Havuz Atıfları 0
Yazar Sayısı 7