CANLI
Yükleniyor Veriler getiriliyor…
/ Makaleler / Scopus Detay
Scopus YÖKSİS DOI Eşleşti SJR Q2

Comparison of 21 and 27 gauge needles for determining sample adequacy in the aspiration biopsy of thyroid nodules

Diagnostic and Interventional Radiology · Ocak 2012

Özet
PURPOSE: To compare 21 and 27 gauge (G) needles used for fine-needle aspiration (FNA) of thyroid nodules to obtain better specimens for adequacy and cytological diagnosis. MATERIALS AND METHODS: One hundred patients with thyroid nodules (100 nodules) were included in this study. Each nodule was aspirated with both 27 G and 21 G needles. The obtained aspirates were classified as adequate and inadequate by two separate cytopathologists. The results were analyzed by appropriate statistical methods. RESULTS: There was no statistically significant difference between 21 G and 27 G needles in terms of adequacy, according to each pathologist (P > 0.05). After pathological evaluation with consensus, the adequacy prevalence was the same (84%) for both needle types in all study populations (P > 0.05). According to the ultrasound characteristics of nodules, the prevalence of inadequate samples in patients with hypoechoic or heterogeneous nodules was significantly higher compared with the prevalence of inadequate samples in patients with isoechoic or hyperechoic nodules for both types of needles (P < 0.05). However, according to the size of the needles, there was no significant difference between hypoechoic and heterogeneous nodules or between isoechoic and hyperechoic nodules with regard to the ability to yield adequate samples (P > 0.05). CONCLUSION: The results of our study showed that FNA with 27 G needles can aspirate adequate material for cytopathological diagnosis. The probability of inadequate sample aspiration of hypoechoic and heterogeneous nodules is higher than that for other nodule types. © Turkish Society of Radiology 2012.
25 atıf Ocak 2012 DOI
YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
Comparison of 21 g and 27 g needles for the sample adequacy in the aspiration biopsy of the thyroid nodules
Diagnostic and Interventional Radiology · 2012 SCI-Expanded
Prof. Dr. NEVZAT SERDAR UĞRAŞ →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 14 kaydı bulundu.
Computed tomography and magnetic resonance imaging findings in congenital cardiovascular anomalies
2025 ISSN: 1305-3825 SCI-Expanded Q3
Prof. Dr. MUSTAFA KOPLAY →
Letter to the Editor: Refining the double-loop drainage catheter
2026 ISSN: 1305-3825 SCI-Expanded Q2
Dr. Öğr. Üyesi İSMAİL DİLEK →
Letter to the Editor: Routine desmopressin before non-focal renal biopsy: is the evidence sufficient?
2026 ISSN: 1305-3825 SCI-Expanded
Dr. Öğr. Üyesi İSMAİL DİLEK →
Letter to the Editor: Reconsidering the role of the pleural tail sign in predicting severe pneumothorax after computed tomography-guided lung biopsy
2026 ISSN: 1305-3825 SCI-Expanded Q2
Dr. Öğr. Üyesi İSMAİL DİLEK →
CT measurement of trunk muscle areas in patients with chronic low back pain
2007 ISSN: 1305-3825 SCI-Expanded
Prof. Dr. FUNDA LEVENDOĞLU →
A novel modified PAIR technique using a trocar catheter for percutaneous treatment of liver hydatid cysts a six year experience
2015 ISSN: 13053825 SCI-Expanded
Prof. Dr. ALAADDİN NAYMAN →
Application of first pass contrast bolus tracking sequence for the assessment of morphology and flow dynamics in cardiac MRI
2013 ISSN: 1305-3825 SCI-Expanded
Prof. Dr. ALAADDİN NAYMAN →
Comparison of apparent diffusion coefficient values among different MRI platforms a multicenter phantom study
2013 ISSN: 13053825 SCI-Expanded
Prof. Dr. MUSTAFA KOPLAY →
Comparison of apparent diffusion coefficient values among different MRI platforms a multicenter phantom study
2013 ISSN: 13053825 SCI-Expanded
Prof. Dr. FATİH KARA →
Magnetic resonance cholangiopancreatography evaluation of intrahepatic bile duct variations with updated classification
2016 ISSN: 13053825 SCI-Expanded
Prof. Dr. ALAADDİN NAYMAN →
Comparison of 21 g and 27 g needles for the sample adequacy in the aspiration biopsy of the thyroid nodules
2012 ISSN: 1305-3825 SCI-Expanded
Prof. Dr. NEVZAT SERDAR UĞRAŞ →
Magnetic resonance cholangiopancreatography evaluation of intrahepatic bile duct variations with updated classification
2016 ISSN: 13053825 SCI-Expanded Q3
Dr. Öğr. Üyesi SEYİT EROL →
MRI of pneumonia in immunocompromised patients: comparison with CT
2017 ISSN: 13053825 SCI-Expanded
Prof. Dr. MEHMET ÖZTÜRK →
Computed tomography and magnetic resonance imaging findings in congenital cardiovascular anomalies
2025 ISSN: 1305-3825 SCI-Expanded Q3
Dr. Öğr. Üyesi NUSRET SEHER →

Makale Bilgileri

Toplam Atıf 25 atıf · Scopus
ISSN13053825
Yayın TarihiOcak 2012
Cilt / Sayfa18 · 102-105

Kurumlar

Ataturk Training and Research Hospital
Izmir Turkey
Selçuk Üniversitesi
Selçuklu Turkey

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 25.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi (ISSN Eşleşmesi)
Diagnostic and Interventional Radiology
Q2 OA
SJR Skoru0,686
H-Index61
YayıncıGalenos Publishing House
ÜlkeTurkey
Cardiology and Cardiovascular Medicine (Q2)
Radiology, Nuclear Medicine and Imaging (Q2)
Dergi sayfasına git

Metrikler

25
Atıf

Sistemimizdeki Yazarlar