Purpose: To compare the results of central corneal thickness (CCT) measurements obtained using optical low-coherence reflectometry (OLCR), Fourier domain optical coherence tomography (FD-OCT), and a Scheimpflug camera (SC), combined with Placido corneal topography. Methods: A total of 25 healthy subjects were enrolled in the present study, and one eye of each subject was included. A detailed ophthalmic examination was performed in all cases following CCT measurements with OLCR, FD-OCT, and SC. The results were compared using an ANOVA test. Bland-Altman analysis was used to demonstrate agreement between methods. Intra-examiner repeatability was assessed by using intraclass correlation coefficients (ICCs). Results: Statistically significant differences were observed between the results of the CCT measurements obtained using the three different devices (p=0.009). Significant correlations were found between OLCR and FD-OCT (r=0.97; p<0.0001), FD-OCT and SC (r=0.91; p<0.0001), and OLCR and SC (r=0.95; p<0.0001). The 95% limits of agreement (LOA) obtained from Bland-Altman plots were from -7.2 μm to 28.7 μm for OLCR versus FD-OCT, from -19.2 μm to 30.4 μm for OLCR versus SC, and from -42.6 to 32.3 μm for FD-OCT versus SC. Intra-examiner repeatability was excellent for each method, with ICCs >0.98. Conclusions: Although the results of CCT measurements obtained from these three devices were highly correlated with one another and the mean differences between instruments were comparable with the reported diurnal CCT fluctuation, the measurements are not directly interchangeable in clinical practice because of the wide LOA values.
Web of Science Eşleşmesi Bulundu
9
WoS Atıf
77
Cilt
Article
Belge Türü
Kaynak: ARQUIVOS BRASILEIROS DE OFTALMOLOGIA
· s. 345-350
Anahtar Kelimeler (WoS)
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 13.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi
Otomatik ISSN Eşleştirmesi
2014 yılı verileri
Arquivos Brasileiros de Oftalmologia
Q3
SJR Quartile
0,281
SJR Skoru
37
H-Index
🔓
Açık Erişim
Kategoriler: Medicine (miscellaneous) (Q3) · Ophthalmology (Q3)
Alanlar: Medicine
Ülke: Brazil
· Conselho Brasileiro De Oftalmologia
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir.
Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.
Anahtar Kelimeler
Cornea/anatomy & histology
Corneal topography/methods
Tomography
optical coherence/methods
Fourier analysis
Comparative study
Observer variation
WoS |
Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.
Makale Bilgileri
Dergi
Arquivos Brasileiros de Oftalmologia
ISSN
0004-2749
Yıl
2014
/ 1. ay
Cilt / Sayı
77
/ 6
Sayfalar
345 – 59
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SCI-Expanded
Yayın Dili
İngilizce
Kapsam
Uluslararası
Toplam Yazar
4 kişi
Erişim Türü
Elektronik
Alan
Sağlık Bilimleri Temel Alanı-
Göz Hastalıkları
YÖKSİS Yazar Kaydı
Yazar Adı
GÖNÜL ŞABAN,TURĞUT ÖZTÜRK BANU,BAKBAK BERKER,GEDİK ŞANSAL
YÖKSİS ID
630147