CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded Özgün Makale Scopus
Comparison of central corneal thickness measurements using optical low-coherence reflectometry, Fourier domain optical coherence tomography, and Scheimpflug camera
Arquivos Brasileiros de Oftalmologia 2014 Cilt 77 Sayı 6
Scopus Eşleşmesi Bulundu
13
Atıf
77
Cilt
345-350
Sayfa
🔓
Açık Erişim
Özet
Purpose: To compare the results of central corneal thickness (CCT) measurements obtained using optical low-coherence reflectometry (OLCR), Fourier domain optical coherence tomography (FD-OCT), and a Scheimpflug camera (SC), combined with Placido corneal topography. Methods: A total of 25 healthy subjects were enrolled in the present study, and one eye of each subject was included. A detailed ophthalmic examination was performed in all cases following CCT measurements with OLCR, FD-OCT, and SC. The results were compared using an ANOVA test. Bland-Altman analysis was used to demonstrate agreement between methods. Intra-examiner repeatability was assessed by using intraclass correlation coefficients (ICCs). Results: Statistically significant differences were observed between the results of the CCT measurements obtained using the three different devices (p=0.009). Significant correlations were found between OLCR and FD-OCT (r=0.97; p<0.0001), FD-OCT and SC (r=0.91; p<0.0001), and OLCR and SC (r=0.95; p<0.0001). The 95% limits of agreement (LOA) obtained from Bland-Altman plots were from -7.2 μm to 28.7 μm for OLCR versus FD-OCT, from -19.2 μm to 30.4 μm for OLCR versus SC, and from -42.6 to 32.3 μm for FD-OCT versus SC. Intra-examiner repeatability was excellent for each method, with ICCs >0.98. Conclusions: Although the results of CCT measurements obtained from these three devices were highly correlated with one another and the mean differences between instruments were comparable with the reported diurnal CCT fluctuation, the measurements are not directly interchangeable in clinical practice because of the wide LOA values.
Web of Science Eşleşmesi Bulundu
9
WoS Atıf
77
Cilt
Article
Belge Türü
Kaynak: ARQUIVOS BRASILEIROS DE OFTALMOLOGIA · s. 345-350
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 13.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2014 yılı verileri
Arquivos Brasileiros de Oftalmologia
Q3
SJR Quartile
0,281
SJR Skoru
37
H-Index
🔓
Açık Erişim
Kategoriler: Medicine (miscellaneous) (Q3) · Ophthalmology (Q3)
Alanlar: Medicine
Ülke: Brazil · Conselho Brasileiro De Oftalmologia
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

Makale Bilgileri

Dergi Arquivos Brasileiros de Oftalmologia
ISSN 0004-2749
Yıl 2014 / 1. ay
Cilt / Sayı 77 / 6
Sayfalar 345 – 59
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 4 kişi
Erişim Türü Elektronik
Alan Sağlık Bilimleri Temel Alanı- Göz Hastalıkları

YÖKSİS Yazar Kaydı

Yazar Adı GÖNÜL ŞABAN,TURĞUT ÖZTÜRK BANU,BAKBAK BERKER,GEDİK ŞANSAL
YÖKSİS ID 630147

Metrikler

Scopus Atıf 13
Havuz Atıfları 0
Yazar Sayısı 4