Comparison of central corneal thickness measurements using optical low-coherence reflectometry, Fourier domain optical coherence tomography, and Scheimpflug camera
Arquivos Brasileiros De Oftalmologia · Ocak 2014
Özet
Purpose: To compare the results of central corneal thickness (CCT) measurements obtained using optical low-coherence reflectometry (OLCR), Fourier domain optical coherence tomography (FD-OCT), and a Scheimpflug camera (SC), combined with Placido corneal topography. Methods: A total of 25 healthy subjects were enrolled in the present study, and one eye of each subject was included. A detailed ophthalmic examination was performed in all cases following CCT measurements with OLCR, FD-OCT, and SC. The results were compared using an ANOVA test. Bland-Altman analysis was used to demonstrate agreement between methods. Intra-examiner repeatability was assessed by using intraclass correlation coefficients (ICCs). Results: Statistically significant differences were observed between the results of the CCT measurements obtained using the three different devices (p=0.009). Significant correlations were found between OLCR and FD-OCT (r=0.97; p<0.0001), FD-OCT and SC (r=0.91; p<0.0001), and OLCR and SC (r=0.95; p<0.0001). The 95% limits of agreement (LOA) obtained from Bland-Altman plots were from -7.2 μm to 28.7 μm for OLCR versus FD-OCT, from -19.2 μm to 30.4 μm for OLCR versus SC, and from -42.6 to 32.3 μm for FD-OCT versus SC. Intra-examiner repeatability was excellent for each method, with ICCs >0.98. Conclusions: Although the results of CCT measurements obtained from these three devices were highly correlated with one another and the mean differences between instruments were comparable with the reported diurnal CCT fluctuation, the measurements are not directly interchangeable in clinical practice because of the wide LOA values.
YÖKSİS Kayıtları
Comparison of central corneal thickness measurements using optical low-coherence reflectometry, Fourier domain optical coherence tomography, and Scheimpflug camera
Arquivos Brasileiros de Oftalmologia · 2014 SCI-Expanded
Prof. Dr. ŞABAN GÖNÜL →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 9 kaydı bulundu.
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 9 kaydı bulundu.
Comparison of central corneal thickness measurements using optical low-coherence reflectometry, Fourier domain optical coherence tomography, and Scheimpflug camera
2014 ISSN: 0004-2749 SCI-Expanded
Prof. Dr. ŞABAN GÖNÜL →
Postoperative fungal endophthalmitis caused by Trichosporon asahii treated with voriconazole
2015 ISSN: 0004-2749 SCI-Expanded
Prof. Dr. SÜLEYMAN OKUDAN →
Bilateral acute iris transillumination BAIT initially misdiagnosed as acute iridocyclitis
2015 ISSN: 0004-2749 SCI-Expanded
Prof. Dr. ŞABAN GÖNÜL →
Metallic corneal foreign bodies an occupational health hazard
2014 ISSN: 0004-2749 SCI-Expanded
Prof. Dr. BANU BOZKURT →
Bilateral acute depigmentation of the iris BADI first reported case in Brazil
2014 ISSN: 0004-2749 SCI-Expanded
Prof. Dr. BANU BOZKURT →
Postoperative fungal endophthalmitis caused by Trichosporon asahii treated with voriconazole
2015 ISSN: 0004-2749 SCI-Expanded
Prof. Dr. ŞABAN GÖNÜL →
Metallic corneal foreign bodies: an occupational health hazard
2014 ISSN: 0004-2749 SCI-Expanded
Prof. Dr. ŞABAN GÖNÜL →
Bilateral acute depigmentation of the iris (BADI): first reported case in Brazil
2014 ISSN: 0004-2749 SCI-Expanded
Prof. Dr. ŞABAN GÖNÜL →
Comparing the effects of serum GPER-1 and oxidant/antioxidant levels on retinopathy in patients with diabetes and healthy individuals: a pilot study
2022 ISSN: 0004-2749 SCI-Expanded
Doç. Dr. ABDULLAH BEYOĞLU →
Makale Bilgileri
Toplam Atıf
13 atıf
· Scopus
ISSN00042749
Yayın TarihiOcak 2014
Cilt / Sayfa77 · 345-350
Scopus ID2-s2.0-84922008924
Erişim🔓 Açık Erişim
Kurumlar
Selçuk Tip Fakültesi
Konya Turkey
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 13.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi (ISSN Eşleşmesi)
Arquivos Brasileiros de Oftalmologia
Q3
OA
SJR Skoru0,350
H-Index39
YayıncıConselho Brasileiro De Oftalmologia
ÜlkeBrazil
Medicine (miscellaneous) (Q3)
Ophthalmology (Q3)
Metrikler
13
Atıf