CANLI
Yükleniyor Veriler getiriliyor…
/ Makaleler / Scopus Detay
Scopus 🔓 Açık Erişim YÖKSİS DOI Eşleşti SJR Q2

The evaluation of doxorubicin-induced cardiotoxicity: Comparison of Doppler and tissue Doppler-derived myocardial performance index

Cardiology Journal · Temmuz 2012

Özet
Background: Doxorubicin is a chemotherapeutic agent used in a wide spectrum of cancers. However, cardiotoxic effects have limited its clinical use. The early detection of doxorubicin-induced cardiotoxicity is crucial. The purpose of our study was to assess values of Doppler and tissue Doppler imaging (TDI)-derived myocardial performance index (MPI) in adult cancer patients receiving doxorubicin treatment. Methods: A total of 45 patients underwent echocardiographic examinations before any doxorubicin had been administered and then after doxorubicin. Doppler and TDI-derived MPI of left ventricular (LV) were determined in the evaluation of cardiotoxicity. Additionally, TDI-derived MPI of right ventricular (RV) was determined. Results: All patients underwent control echocardiographic examination after mean 5 ± 1.7 months. The LV MPI obtained by both Doppler and TDI were increased after doxorubicin treatment (0.56 ± 0.11, 0.61 ± 0.10, p = 0,005 vs 0.51 ± 0.09, 0.59 ± 0.09, p = 0.001, respectively). There was no correlation between Doppler-derived MPI and cumulative doxorubicin dose (coefficient of correlation 0.11, p = 0.6). TDI-derived MPI was correlated with cumulative doxorubicin dose (coefficient of correlation 0.35, p = 0.015), but this correlation is weak (r = 0.38). The study population was divided into two groups according to doxorubicin dose (below and above 300 mg level). There was a moderate correlation between TDI-derived MPI and less than 300 mg of doxorubicin dose (coefficient of correlation 0.51, p = 0.028). However, Doppler-derived MPI was not correlated with less than 300 mg of doxorubicin dose (coefficient of correlation 0.38, p = 0.123). Also, there was no significant change in the TDI-derived RV-MPI (0.49 ± 0.14, 0.50 ± 0.12, p = 0.56). Conclusions: TDI-derived MPI is a useful parameter and an early indicator compared with Doppler-derived MPI in the detection of cardiotoxicity during the early stages. Also, doxorubicin administration does not affect RV function. © 2012 Via Medica.
18 atıf Temmuz 2012 DOI
YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
The evaluation of doxorubicin induced cardiotoxicity Comparison of Doppler and tissue Doppler derived myocardial performance index
Cardiology Journal · 2012 SCI-Expanded
Prof. Dr. KENAN DEMİR →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 1 kaydı bulundu.
The evaluation of doxorubicin induced cardiotoxicity Comparison of Doppler and tissue Doppler derived myocardial performance index
2012 ISSN: 18975593 SCI-Expanded
Prof. Dr. KENAN DEMİR →

Makale Bilgileri

Toplam Atıf 18 atıf · Scopus
ISSN18975593
Yayın TarihiTemmuz 2012
Cilt / Sayfa19 · 363-368
Erişim🔓 Açık Erişim

Kurumlar

Bolu Abant İzzet Baysal Üniversitesi
Bolu Turkey
Selçuk Üniversitesi
Selçuklu Turkey

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 18.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi (ISSN Eşleşmesi)
Cardiology Journal
Q2 OA
SJR Skoru0,676
H-Index50
YayıncıVia Medica
ÜlkePoland
Cardiology and Cardiovascular Medicine (Q2)
Medicine (miscellaneous) (Q2)
Dergi sayfasına git

Metrikler

18
Atıf

Sistemimizdeki Yazarlar