Scopus
YÖKSİS DOI Eşleşti
SJR Q1
Effect of religious fasting on tear osmolarity and ocular surface
Eye and Contact Lens · Ocak 2014
Özet
Objective: To evaluate the effects of religious fasting on tear secretion, tear osmolarity, corneal topography, and ocular aberrations. Methods: This prospective controlled study comprised 29 eyes of 29 healthy men. Before ophthalmologic examination, all subjects underwent corneal topography by a placido disc corneal topography and aberrometry device (OPD Scan II). Tear osmolarity was measured using OcuSense TearLab osmometer. Ocular surface disease index (OSDI) scores, tear break-up time (BUT), Schirmer I test, and lissamine green staining were evaluated. The measurements taken before and during Ramadan at the same hours between 4.00 and 5.00 PM were compared using paired sample t test, and a P value less than 0.05 was accepted as statistically significant. Results: The mean age of the study group was 27.8±5.9 years (range, 20-47 years). The mean tear osmolarity values were measured as 285. ±68.2 mOsm/L and 293.3±16.0 mOsm/L, whereas the mean Schirmer I values were 14.866.0 mm and 10.6±5.3 mm in nonfasting and fasting periods, respectively. Tear osmolarity, OSDI, and Oxford grading scores significantly increased (P=0.02, P=0.002, P=0.003, respectively), whereas Schirmer I values and intraocular pressure decreased (both, P < 0.001) during the fasting period compared with the nonfasting period. There were no significant differences in tear BUT, keratometry values, and corneal aberration measurements between nonfasting and fasting periods (P>0.05, for all). Conclusion: Fasting significantly decreases tear production and increases tear osmolarity; however, it does not deteriorate corneal topographic parameters and ocular aberrations in healthy subjects.
YÖKSİS Kayıtları
Effect of Religious Fasting on Tear Osmolarity and Ocular Surface
Eye Contact Lens: Science Clinical Practice · 2014 SCI-Expanded
Prof. Dr. SÜLEYMAN OKUDAN →
Effect of Religious Fasting on Tear Osmolarity and Ocular Surface
Eye & Contact Lens: Science & Clinical Practice · 2014 SCI-Expanded
Prof. Dr. BANU BOZKURT →
Effect of Religious Fasting on Tear Osmolarity and Ocular Surface
Eye Contact Lens: Science Clinical Practice · 2014 SCI-Expanded
Prof. Dr. ŞABAN GÖNÜL →
Effect of Religious Fasting on Tear Osmolarity and Ocular Surface
Eye & Contact Lens: Science & Clinical Practice · 2014 SCI-Expanded
Prof. Dr. ŞABAN GÖNÜL →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 5 kaydı bulundu.
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 5 kaydı bulundu.
The Effect of Room Illumination on the Measurement of Anterior Segment Parameters
2014 ISSN: 1542-2321 SCI-Expanded
Prof. Dr. ŞABAN GÖNÜL →
Effect of Religious Fasting on Tear Osmolarity and Ocular Surface
2014 ISSN: 1542-2321 SCI-Expanded
Prof. Dr. ŞABAN GÖNÜL →
Effect of Religious Fasting on Tear Osmolarity and Ocular Surface
2014 ISSN: 1542-2321 SCI-Expanded
Prof. Dr. BANU BOZKURT →
Effect of Religious Fasting on Tear Osmolarity and Ocular Surface
2014 ISSN: 1542-2321 SCI-Expanded
Prof. Dr. SÜLEYMAN OKUDAN →
Long-Term Monitoring of an Intracorneal Bee Stinger Using Anterior Segment Optical Coherence Tomography and In Vivo Confocal Microscopy
2026 ISSN: 1542-2321 SCI-Expanded Q2
Dr. Öğr. Üyesi AYŞE BOZKURT OFLAZ →
Makale Bilgileri
Dergi
Eye and Contact Lens
Toplam Atıf
22 atıf
· Scopus
ISSN15422321
Yayın TarihiOcak 2014
Cilt / Sayfa40 · 239-242
Scopus ID2-s2.0-84905465541
Kurumlar
Selçuk Tip Fakültesi
Konya Turkey
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 22.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi (ISSN Eşleşmesi)
Eye and Contact Lens
Q1
SJR Skoru0,852
H-Index74
YayıncıLippincott Williams and Wilkins
ÜlkeUnited States
Ophthalmology (Q1)
Medicine (miscellaneous) (Q2)
Metrikler
22
Atıf