Scopus
YÖKSİS DOI Eşleşti
SJR Q1
Cardiac autoantibody levels predict recurrence following cryoballoon-based pulmonary vein isolation in paroxysmal atrial fibrillation patients
Journal of Cardiovascular Electrophysiology · Haziran 2015
Özet
Cardiac Autoantibodies and AF Recurrence Introduction Recent evidence has suggested that autoantibodies may play an important role in the development of atrial fibrillation (AF). The predictive value of preprocedural autoantibodies against beta-1 adrenergic receptor (anti-β1-R) and M2-muscarinic acetylcholine receptor (anti-M2-R) for AF recurrence following cryoballoon-based pulmonary vein isolation (PVI) is still unclear. We aimed to determine the predictive value of preprocedural anti-β1-R and anti-M2-R levels for AF recurrence. Methods Eighty patients (mean age 54.25 ± 7.70 years; 40% female) with paroxysmal AF and preserved left ventricular function who underwent cryoballoon-based PVI were included in the study. Preprocedural anti-M2-R and anti-β1-R levels were measured with ELISA. Results At 1-year follow-up after ablation, late AF recurrence was observed in 17 (21.25%) patients. In the Cox regression model, including number of antiarrhythmic drugs, early AF recurrence, anti-β1-R levels >159.88 ng/mL, anti-M2-R levels >277.65 ng/mL, AF duration, and left atrial volume index, only anti-β1-R levels >159.88 ng/mL (HR: 4.281, P = 0.039) and anti-M2-R levels >277.65 ng/mL (HR: 4.313, P = 0.030) were found to be independent predictors of late AF recurrence. Anti-β1-R level >159.88 ng/mL was shown to predict late AF recurrence with a sensitivity of 70.59% and specificity of 90.48%. A cut-off value of 277.65 ng/mL for anti-M2-R level predicted AF recurrence with a sensitivity of 70.59% and specificity of 95.24%. Conclusion Preprocedural serum anti-β1-R and anti-M2-R levels are independent predictors of late AF recurrence following cryoballoon-based PVI in paroxysmal AF patients. Detection of preprocedural anti-β1-R and anti-M2-R levels may serve as a novel method for determination of paroxysmal AF patients who may not benefit from cryoballoon-based PVI.
YÖKSİS Kayıtları
Cardiac Autoantibody Levels Predict Recurrence Following Cryoballoon Based Pulmonary Vein Isolation in Paroxysmal Atrial Fibrillation Patients
Journal of Cardiovascular Electrophysiology · 2015 SCI
Doç. Dr. KADRİ MURAT GÜRSES →
Cardiac Autoantibody Levels Predict Recurrence Following Cryoballoon Based Pulmonary Vein Isolation in Paroxysmal Atrial Fibrillation Patients
Journal of Cardiovascular Electrophysiology · 2015 SCI-Expanded
Doç. Dr. MUHAMMED ULVİ YALÇIN →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 10 kaydı bulundu.
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 10 kaydı bulundu.
Cardiac Autoantibody Levels Predict Recurrence Following Cryoballoon Based Pulmonary Vein Isolation in Paroxysmal Atrial Fibrillation Patients
2015 ISSN: 10453873 SCI
Doç. Dr. KADRİ MURAT GÜRSES →
The Association of Serum Galectin 3 Levels with Atrial Electrical and Structural Remodeling
2015 ISSN: 10453873 SCI
Doç. Dr. KADRİ MURAT GÜRSES →
Cardiac Autoantibody Levels Predict Recurrence Following Cryoballoon Based Pulmonary Vein Isolation in Paroxysmal Atrial Fibrillation Patients
2015 ISSN: 10453873 SCI-Expanded
Doç. Dr. MUHAMMED ULVİ YALÇIN →
The Association of Serum Galectin 3 Levels with Atrial Electrical and Structural Remodeling
2015 ISSN: 10453873 SCI-Expanded
Doç. Dr. MUHAMMED ULVİ YALÇIN →
Dynamic changes in atrial activation sequence during supraventricular tachycardia
2022 ISSN: 1045-3873 SCI-Expanded Q3
Prof. Dr. ABDULLAH TUNÇEZ →
Unusual response to His‐synchronous ventricular stimulation during a supraventricular tachycardia: Atrial advancement with or without resetting?
2022 ISSN: 1045-3873 SCI-Expanded Q3
Prof. Dr. ABDULLAH TUNÇEZ →
Widening of the QRS complex during the wide complex tachycardia: What is the mechanism?
2022 ISSN: 1045-3873 SCI-Expanded Q3
Prof. Dr. ABDULLAH TUNÇEZ →
Entrainment of ventricular tachycardia with V‐shaped diastolic activation pattern: Is the pacing site in or out?
2022 ISSN: 1045-3873 SCI-Expanded Q3
Prof. Dr. ABDULLAH TUNÇEZ →
Simultaneous narrow and wide QRS complex tachycardia: Misdiagnosis or missed diagnosis?
2022 ISSN: 1045-3873 SCI-Expanded Q3
Prof. Dr. ABDULLAH TUNÇEZ →
Transition from two wide to a narrow QRS complex tachycardia: What is the mechanism of tachycardia and transition?
2022 ISSN: 1045-3873 SCI-Expanded Q3
Prof. Dr. ABDULLAH TUNÇEZ →
Makale Bilgileri
Toplam Atıf
17 atıf
· Scopus
ISSN10453873
Yayın TarihiHaziran 2015
Cilt / Sayfa26 · 615-621
Scopus ID2-s2.0-84930764708
Kurumlar
Hacettepe Üniversitesi
Ankara Turkey
Kars Harakani State Hospital
Kars Turkey
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 17.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi (ISSN Eşleşmesi)
Journal of Cardiovascular Electrophysiology
Q1
SJR Skoru0,953
H-Index157
YayıncıJohn Wiley and Sons Inc
ÜlkeUnited States
Cardiology and Cardiovascular Medicine (Q1)
Physiology (medical) (Q2)
Metrikler
17
Atıf