CANLI
Yükleniyor Veriler getiriliyor…
/ Makaleler / Scopus Detay
Scopus YÖKSİS DOI Eşleşti SJR Q1

Periatrial epicardial adipose tissue thickness is an independent predictor of atrial fibrillation recurrence after cryoballoon-based pulmonary vein isolation

Journal of Cardiovascular Computed Tomography · Temmuz 2015

Özet
Background: Epicardial adipose tissue (EAT) is a metabolically active fat depot. Studies have investigated the effect of EAT thickness on outcomes of radiofrequency catheter ablation of atrial fibrillation (AF). However, data on the relationship between EAT thickness and outcome of cryoballoon-based pulmonary vein isolation (PVI) are lacking. Objective: In this study, we investigate the association between EAT thickness and AF recurrence after cryoballoon-based PVI. Methods: Patients with symptomatic paroxysmal or persistent AF despite ≥1 antiarrhythmic drug(s) were scheduled for cryoballoon-based PVI for AF per the recent recommendations. Periatrial, periventricular, and total EAT thickness measurements were obtained from preprocedural multidetector CT scans. Results: A total of 249 patients (55.6 ± 10.7 years; 48.2% male; 18.5% persistent AF) were involved in the study. Patients were followed-up for 29 months (8-48 months). When blanking period was considered, freedom from AF after the ablation procedure was 75.9% at a median follow-up of 29 months. Total periatrial EAT thickness (18.1 ± 6.2 vs 14.7 ± 4.7 mm; P < .001) was greater in patients with late AF recurrence when compared to those without. On the other hand, periventricular or total EAT thickness measurements did not differ between both groups (. P > .05). Multivariate Cox proportional hazard regression analysis showed that periatrial EAT thickness (hazard ratio, 1.086; P = .001) and left atrial volume index (hazard ratio, 1.144; P < .001) were independent predictors for late AF recurrence. Conclusion: Quantification of EAT thickness from preprocedural multidetector CT scans may serve as a beneficial parameter for prediction of AF recurrence after cryoballoon-based PVI.
53 atıf Temmuz 2015 DOI
YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
Periatrial epicardial adipose tissue thickness is an independent predictor of atrial fibrillation recurrence after cryoballoon based pulmonary vein isolation
Journal of Cardiovascular Computed Tomography · 2015 SCI-Expanded
Doç. Dr. KADRİ MURAT GÜRSES →
Periatrial epicardial adipose tissue thickness is an independent predictor of atrial fibrillation recurrence after cryoballoon based pulmonary vein isolation
Journal of Cardiovascular Computed Tomography · 2015 SCI-Expanded
Doç. Dr. MUHAMMED ULVİ YALÇIN →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 4 kaydı bulundu.
Periatrial epicardial adipose tissue thickness is an independent predictor of atrial fibrillation recurrence after cryoballoon based pulmonary vein isolation
2015 ISSN: 19345925 SCI-Expanded
Doç. Dr. KADRİ MURAT GÜRSES →
Periatrial epicardial adipose tissue thickness is an independent predictor of atrial fibrillation recurrence after cryoballoon based pulmonary vein isolation
2015 ISSN: 19345925 SCI-Expanded
Doç. Dr. MUHAMMED ULVİ YALÇIN →
Pulmonary vein orientation is independently associated with outcomes following cryoballoon-based atrial fibrillation ablation
2018 ISSN: 1934-5925 SCI-Expanded
Doç. Dr. KADRİ MURAT GÜRSES →
Impact of anatomical features of the left atrial appendage on outcomes after cryoablation for atrial fibrillation
2019 ISSN: 1934-5925 SCI-Expanded
Doç. Dr. KADRİ MURAT GÜRSES →

Makale Bilgileri

Toplam Atıf 53 atıf · Scopus
ISSN19345925
Yayın TarihiTemmuz 2015
Cilt / Sayfa9 · 295-302

Kurumlar

Hacettepe Üniversitesi
Ankara Turkey
Konya Meram Training and Research Hospital
Konya Turkey
T. C. Sağlık Bakanlığı Hakkari Devlet Hastanesi
Hakkari Turkey

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 53.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi (ISSN Eşleşmesi)
Journal of Cardiovascular Computed Tomography
Q1
SJR Skoru1,708
H-Index75
YayıncıElsevier Inc.
ÜlkeUnited States
Cardiology and Cardiovascular Medicine (Q1)
Radiology, Nuclear Medicine and Imaging (Q1)
Dergi sayfasına git

Metrikler

53
Atıf

Sistemimizdeki Yazarlar