The effect of room illumination on the measurement of anterior segment parameters
Eye and Contact Lens · Ocak 2014
Özet
OBJECTIVE:: To evaluate the effect of room illumination on the measurement of anterior segment parameters. METHODS:: In this comparative study, measurements of anterior segment parameters of 25 eyes of 25 healthy patients were performed by optical low-coherence reflectometry (OLCR). Measurements were taken under photopic conditions (150 lux) and under mesopic conditions (3 lux). Paired t test by SPSS 16.0 was used to compare the anterior segment measurements performed in both conditions. A P value lower than 0.05 was accepted as statistically significant. RESULTS:: The mean age of the patients was 27.09±1.72 years (range, 20-40 years). Of the anterior segment parameters, axial length and keratometry did not show significant difference between photopic and mesopic conditions (P=0.541 and P=0.812, respectively). The mean anterior chamber depth measurements was 3.04±0.35 mm and 3.06±0.35 mm, whereas the mean lens thickness was 3.75±0.36 mm and 3.77±0.36 mm in the mesopic and photopic conditions, respectively. The mean pupil diameter measurement was 4.86±0.70 mm under photopic conditions and 6.36±0.94 mm under mesopic conditions. The anterior chamber depth, lens thickness, and pupil diameter showed significant difference between photopic and mesopic conditions (P=0.01, P=0.006, and P=0.0001, respectively). CONCLUSION:: Anterior chamber depth, lens thickness, and pupil diameter were affected by the changes in luminance while performing measurements with OLCR. Considering the age of the study group, further studies are needed to test the measurement of accommodation amplitude. © 2014 Contact Lens Association of Ophthalmologists.
YÖKSİS Kayıtları
The Effect of Room Illumination on the Measurement of Anterior Segment Parameters
Eye & Contact Lens: Science & Clinical Practice · 2014 SCI-Expanded
Prof. Dr. ŞABAN GÖNÜL →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 5 kaydı bulundu.
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 5 kaydı bulundu.
The Effect of Room Illumination on the Measurement of Anterior Segment Parameters
2014 ISSN: 1542-2321 SCI-Expanded
Prof. Dr. ŞABAN GÖNÜL →
Effect of Religious Fasting on Tear Osmolarity and Ocular Surface
2014 ISSN: 1542-2321 SCI-Expanded
Prof. Dr. ŞABAN GÖNÜL →
Effect of Religious Fasting on Tear Osmolarity and Ocular Surface
2014 ISSN: 1542-2321 SCI-Expanded
Prof. Dr. BANU BOZKURT →
Effect of Religious Fasting on Tear Osmolarity and Ocular Surface
2014 ISSN: 1542-2321 SCI-Expanded
Prof. Dr. SÜLEYMAN OKUDAN →
Long-Term Monitoring of an Intracorneal Bee Stinger Using Anterior Segment Optical Coherence Tomography and In Vivo Confocal Microscopy
2026 ISSN: 1542-2321 SCI-Expanded Q2
Dr. Öğr. Üyesi AYŞE BOZKURT OFLAZ →
Makale Bilgileri
Dergi
Eye and Contact Lens
Toplam Atıf
1 atıf
· Scopus
ISSN15422321
Yayın TarihiOcak 2014
Cilt / Sayfa40 · 181-184
Scopus ID2-s2.0-84899933888
Kurumlar
Selçuk Üniversitesi
Selçuklu Turkey
World Eye Hospital
Istanbul Turkey
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 1.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi (ISSN Eşleşmesi)
Eye and Contact Lens
Q1
SJR Skoru0,852
H-Index74
YayıncıLippincott Williams and Wilkins
ÜlkeUnited States
Ophthalmology (Q1)
Medicine (miscellaneous) (Q2)
Metrikler
1
Atıf