CANLI
Yükleniyor Veriler getiriliyor…
/ Makaleler / Scopus Detay
Scopus 🔓 Açık Erişim YÖKSİS DOI Eşleşti SJR Q2

A comparison between two different automated total 25-hydroxyvitamin D immunoassay methods using liquid chromatography-tandem mass spectrometry

Biochemia Medica · Ocak 2015

Özet
Introduction: Total 25-hydroxyvitamin D [25(OH)D] is the most reliable indicator of vitamin D status. In this study, we compared two automated immunoassay methods, the Abbott Architect 25-OH Vitamin D assay and the Roche Cobas Vitamin D total assay, with the liquid chromatographytandem mass spectrometry (LC-MS/MS). Materials and methods: One hundred venous blood samples were randomly selected from routine vitamin D tests. Two of the serum aliquots were analyzed at the Abbott Architect i2000 and the Roche Cobas 6000’s module e601 in our laboratory within the same day. The other serum aliquots were analyzed at the LC-MS/MS in different laboratory. Passing-Bablok regression analysis and Bland-Altman plot were used to compare methods. Inter-rater agreement was analyzed using kappa (κ) analysis. Results: The Roche assay showed acceptable agreement with the LC-MS/MS based on Passing-Bablok analysis (intercept: -5.23 nmol/L, 95% CI: -8.73 to 0.19; slope: 0.97, 95% CI: 0.77 to 1.15). The Abbott assay showed proportional (slope: 0.77, 95% CI: 0.67 to 0.85) and constant differences (intercept: 17.08 nmol/L; 95% CI: 12.98 to 21.39). A mean bias of 15.1% was observed for the Abbott and a mean bias of -14.1% was observed for the Roche based on the Bland-Altman plots. We found strong to nearly perfect agreement in vitamin D status between the immunoassays and LC-MS/ MS. (κ: 0.83 for Abbott, κ: 0.93 for Roche) using kappa analysis. Conclusion: Both immunoassays demonstrated acceptable performance, but the Roche Cobas assay demonstrated better performance than the Abbott Architect in the studied samples.
27 atıf Ocak 2015 DOI
YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
A comparison between two different automated total 25 hydroxyvitamin D immunoassay methods using liquid chromatography tandem mass spectrometry
Biochemia Medica · 2015 SCI-Expanded
Prof. Dr. BAHADIR ÖZTÜRK →
A comparison between two different automated total 25 hydroxyvitamin D immunoassay methods using liquid chromatography tandem mass spectrometry
Biochemia Medica · 2015 SCI-Expanded
Prof. Dr. ALİ ÜNLÜ →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 2 kaydı bulundu.
A comparison between two different automated total 25 hydroxyvitamin D immunoassay methods using liquid chromatography tandem mass spectrometry
2015 ISSN: 1330-0962 SCI-Expanded
Prof. Dr. BAHADIR ÖZTÜRK →
A nationwide multicentre study in Turkey for establishing reference intervals of haematological parameters with novel use of a panel of whole blood
2017 ISSN: 1330-0962 SCI-Expanded
Prof. Dr. HÜSAMETTİN VATANSEV →

Makale Bilgileri

Toplam Atıf 27 atıf · Scopus
ISSN13300962
Yayın TarihiOcak 2015
Cilt / Sayfa25 · 430-438
Erişim🔓 Açık Erişim

Kurumlar

Dumlupinar Üniversitesi
Kutahya Turkey
Selçuk Üniversitesi
Selçuklu Turkey
T.C. Ministry of Health Kütahya Health Sciences University Evliya Çelebi Education and Research Hospital
Kutahya Turkey

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 27.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi (ISSN Eşleşmesi)
Biochemia Medica
Q2 OA
SJR Skoru0,550
H-Index60
YayıncıBiochemia Medica, Editorial Office
ÜlkeCroatia
Biochemistry (medical) (Q2)
Clinical Biochemistry (Q3)
Dergi sayfasına git

Metrikler

27
Atıf

Sistemimizdeki Yazarlar