Scopus
YÖKSİS DOI Eşleşti
SJR Q2
Comparison of apparent diffusion coefficient values among different MRI platforms: A multicenter phantom study
Diagnostic and Interventional Radiology · Kasım 2013
Özet
Purpose: We aimed to compare apparent diffusion coefficient (ADC) values among magnetic resonance imaging (MRI) scanners from different vendors. Materials and Methods: We used a custom-made phantom solution consisting of distilled water, 0.9% NaCl, 25% NaCl, and shampoo for diffusion-weighted MRI (DW-MRI) examinations. DW-MRI was performed with similar sequence parameters using six different 1.5 Tesla MR scanners (scanners A-F). ADC maps were automatically constructed for all DW-MR images (b factors of 0 and 1000 s/mm2). ADC measurements were performed using regions of interest and seven different software programs, including four different postprocessing workstations, two different picture archiving and communication systems, and operator console software for each MR scanner. Results: The ADC values generated by scanners A and F were higher and those of scanner B were lower than those generated by the other scanners (P = 0.002). The intravendor difference in the ADC values averaged from scanners D, E, and F was statistically significant (P < 0.001). The difference between the ADC values obtained by scanners C and E was not statistically different (P = 0.15). Conclusion: ADC values may differ among different MRI systems used for DW-MRI. Thus, the MRI vendor should be considered when using DW-MRI in a clinical setting. © Turkish Society of Radiology 2013.
YÖKSİS Kayıtları
Comparison of apparent diffusion coefficient values among different MRI platforms a multicenter phantom study
Diagnostic and Interventional Radiology · 2013 SCI-Expanded
Prof. Dr. MUSTAFA KOPLAY →
Comparison of apparent diffusion coefficient values among different MRI platforms a multicenter phantom study
Diagnostic and Interventional Radiology · 2013 SCI-Expanded
Prof. Dr. FATİH KARA →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 14 kaydı bulundu.
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 14 kaydı bulundu.
Computed tomography and magnetic resonance imaging findings in congenital cardiovascular anomalies
2025 ISSN: 1305-3825 SCI-Expanded Q3
Prof. Dr. MUSTAFA KOPLAY →
Letter to the Editor: Refining the double-loop drainage catheter
2026 ISSN: 1305-3825 SCI-Expanded Q2
Dr. Öğr. Üyesi İSMAİL DİLEK →
Letter to the Editor: Routine desmopressin before non-focal renal biopsy: is the evidence sufficient?
2026 ISSN: 1305-3825 SCI-Expanded
Dr. Öğr. Üyesi İSMAİL DİLEK →
Letter to the Editor: Reconsidering the role of the pleural tail sign in predicting severe pneumothorax after computed tomography-guided lung biopsy
2026 ISSN: 1305-3825 SCI-Expanded Q2
Dr. Öğr. Üyesi İSMAİL DİLEK →
CT measurement of trunk muscle areas in patients with chronic low back pain
2007 ISSN: 1305-3825 SCI-Expanded
Prof. Dr. FUNDA LEVENDOĞLU →
A novel modified PAIR technique using a trocar catheter for percutaneous treatment of liver hydatid cysts a six year experience
2015 ISSN: 13053825 SCI-Expanded
Prof. Dr. ALAADDİN NAYMAN →
Application of first pass contrast bolus tracking sequence for the assessment of morphology and flow dynamics in cardiac MRI
2013 ISSN: 1305-3825 SCI-Expanded
Prof. Dr. ALAADDİN NAYMAN →
Comparison of apparent diffusion coefficient values among different MRI platforms a multicenter phantom study
2013 ISSN: 13053825 SCI-Expanded
Prof. Dr. MUSTAFA KOPLAY →
Comparison of apparent diffusion coefficient values among different MRI platforms a multicenter phantom study
2013 ISSN: 13053825 SCI-Expanded
Prof. Dr. FATİH KARA →
Magnetic resonance cholangiopancreatography evaluation of intrahepatic bile duct variations with updated classification
2016 ISSN: 13053825 SCI-Expanded
Prof. Dr. ALAADDİN NAYMAN →
Comparison of 21 g and 27 g needles for the sample adequacy in the aspiration biopsy of the thyroid nodules
2012 ISSN: 1305-3825 SCI-Expanded
Prof. Dr. NEVZAT SERDAR UĞRAŞ →
Magnetic resonance cholangiopancreatography evaluation of intrahepatic bile duct variations with updated classification
2016 ISSN: 13053825 SCI-Expanded Q3
Dr. Öğr. Üyesi SEYİT EROL →
MRI of pneumonia in immunocompromised patients: comparison with CT
2017 ISSN: 13053825 SCI-Expanded
Prof. Dr. MEHMET ÖZTÜRK →
Computed tomography and magnetic resonance imaging findings in congenital cardiovascular anomalies
2025 ISSN: 1305-3825 SCI-Expanded Q3
Dr. Öğr. Üyesi NUSRET SEHER →
Makale Bilgileri
Toplam Atıf
56 atıf
· Scopus
ISSN13053825
Yayın TarihiKasım 2013
Cilt / Sayfa19 · 433-437
Scopus ID2-s2.0-84887268215
Kurumlar
Selçuk Üniversitesi
Selçuklu Turkey
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 56.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi (ISSN Eşleşmesi)
Diagnostic and Interventional Radiology
Q2
OA
SJR Skoru0,686
H-Index61
YayıncıGalenos Publishing House
ÜlkeTurkey
Cardiology and Cardiovascular Medicine (Q2)
Radiology, Nuclear Medicine and Imaging (Q2)
Metrikler
56
Atıf