Scopus
YÖKSİS DOI Eşleşti
SJR Q1
Microleakage of endodontically treated teeth with different dowel systems
Journal of Prosthetic Dentistry · Ağustos 2004
Özet
Statement of problem Several new esthetic dowel systems are available for the restoration of endodontically treated teeth, but little is known about how effectively these dowels seal the restored teeth. Purpose The purpose of this in vitro study was to compare microleakage of 3 esthetic, adhesively luted dowel systems with a conventional dowel system. Material and methods The root canals of 41 human intact single-rooted extracted teeth were prepared using a step-back technique. The teeth were randomly divided into 4 experimental groups (n=10), and 1 tooth served as a positive control. The decoronated roots were obturated with gutta-percha using lateral condensation. Roots were restored with 1 of the following dowel systems according to the manufacturer's instructions: (1) stainless steel dowels (ParaPost), (2) glass fiber dowels (Snowpost), (3) resin-supported polyethylene fiber (Ribbond) dowels, or (4) zirconia dowels (Cosmopost). Using a fluid filtration method, coronal leakage of the specimens along the dowel space and root canal restorative material was measured. Fluid movement measurements were made at 2-minute intervals for 8 minutes to measure the presence of voids existing in the obturated canals, at 1 week, 3 months, and 6 months following dowel insertion. A repeated-measures analysis of variance (ANOVA) was used to analyze logarithmic transformations of data (time and dowel material) for significant differences. The Tukey HSD test and paired 2-tailed tests were used to perform multiple comparisons (α=.05). Results The data indicated that the leakage values varied according to the dowel system used (P<.01). There was significant interaction between dowel systems and time of testing (P<.01). The sealing ability of zirconia dowels decreased over time (P<.01), but sealing abilities of stainless steel and resin-supported polyethylene fiber dowels remained constant (P>.05). The sealing ability of glass fiber dowels increased at 3 months (P=.032) and remained constant over the next 3 months (P=.758). Statistically, resin-supported polyethylene fiber and glass fiber dowels showed the lowest coronal leakage when compared with stainless steel and zirconia dowels at all time periods (P<.01). There were no significant differences between resin-supported polyethylene fiber and glass fiber dowels at any time period. The initial leakage measurement in zirconia dowel and stainless steel dowels were similar (P=.914), but became significantly different at 3 and 6 months (P<.01). Conclusion Resin-supported polyethylene fiber dowels and glass fiber dowels tested exhibited less microleakage compared to zirconia dowel systems. The latter system should be further evaluated because of its unacceptable level of leakage.
YÖKSİS Kayıtları
Microleakage of endodontically treated teeth with different dowel systems
The Journal of Prosthetic Dentistry · 2004 SCI-Expanded
Prof. Dr. SEMA BELLİ →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 11 kaydı bulundu.
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 11 kaydı bulundu.
Microleakage of endodontically treated teeth with different dowel systems
2004 ISSN: 0022-3913 SSCI
Prof. Dr. FUNDA KONT ÇOBANKARA →
Stress analysis of effects of nonrigid connectors on fixed partial dentures with pier abutments
2008 ISSN: 00223913 SCI
Prof. Dr. OĞUZ ERASLAN →
Effect of different finishing techniques for restorative materials on surface roughness and bacterial adhesion
2010 ISSN: 00223913 SSCI
Prof. Dr. İSA YÖNDEM →
Bond strength between root dentin and three glass fiber post systems
2006 ISSN: 00223913 SCI-Expanded
Prof. Dr. SEMA BELLİ →
Microleakage of endodontically treated teeth with different dowel systems
2004 ISSN: 00223913 SCI-Expanded
Prof. Dr. SEMA BELLİ →
Effect of dentin bonding and ferrule preparation on the fracture strength of crowned teeth restored with dowels and amalgam cores
2006 ISSN: 0022-3913 SCI
Prof. Dr. MÜNİR TOLGA YÜCEL →
Use of polyethylene ribbon to create a provisional fixed partial denture after immediate implant placement: A clinical report
2004 ISSN: 00223913 SCI-Expanded
Prof. Dr. SEMA BELLİ →
Effect of fabrication techniques on the optical properties of zirconia-based systems
2021 ISSN: 0022-3913 SCI Q1
Doç. Dr. TUBA YILMAZ SAVAŞ →
Effects of sintering protocol and dipping time on the optical properties of monolithic zirconia
2022 ISSN: 0022-3913 SCI Q1
Doç. Dr. TUBA YILMAZ SAVAŞ →
Design and fabrication of an interim fixed restoration with an open-source nondental CAD software program and additive manufacturing: A technical report
2024 ISSN: 0022-3913 SCI Q1
Doç. Dr. TUBA YILMAZ SAVAŞ →
Fabricating a custom monoblock mandibular advancement device by using an open-source nondental CAD software program and additive manufacturing: A dental technique
2024 ISSN: 0022-3913 SCI Q1
Doç. Dr. TUBA YILMAZ SAVAŞ →
Makale Bilgileri
Toplam Atıf
42 atıf
· Scopus
ISSN00223913
Yayın TarihiAğustos 2004
Cilt / Sayfa92 · 163-169
Scopus ID2-s2.0-4143102667
Kurumlar
Selçuk Üniversitesi
Selçuklu Turkey
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 42.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi (ISSN Eşleşmesi)
Journal of Prosthetic Dentistry
Q1
SJR Skoru1,291
H-Index168
YayıncıElsevier Inc.
ÜlkeUnited States
Medicine (miscellaneous) (Q1)
Oral Surgery (Q1)
Metrikler
42
Atıf