Scopus
YÖKSİS DOI Eşleşti
SJR Q2
Does 2% chlorhexidine digluconate cavity disinfectant or sodium fluoride/hydroxyethyl methacrylate affect adhesion of universal adhesive to dentin?
Journal of Adhesion Science and Technology · Ocak 2016
Özet
The objectives of this study were to investigate the adhesion of a universal adhesive used either in total-etch (TE) or self-etch (SE) mode with and without 2% chlorhexidine digluconate cavity disinfectant (CHX) or sodium fluoride/hydroxyethyl methacrylate (NaF/HEMA) to dentin. Dentin surfaces of extracted human non-carious third molar teeth (N = 18) were exposed and randomly assigned to two groups. Half of the teeth were conditioned with TE and the others with SE adhesive mode. The teeth were then randomly divided into two groups where half were cleaned with 2% CHX (Cavity Cleanser, Bisco, CC) and the other half with NaF/HEMA (Aqua Prep F, Bisco, APF). Control groups in TE (C1) and SE (C2) adhesive system did not receive any cavity disinfectant. Dentin surfaces were conditioned with universal adhesive (Single Bond Universal, SBU) and resin composite blocks (3 M Z550) were bonded incrementally on the conditioned dentin using a mold. The teeth were stored in water for 48 h, and from each tooth, beam-shaped specimens (1 mm2) were prepared (n = 14, per group). Microtensile bond strength (MBS) was measured using a universal testing machine (1 mm/min). Data (MPa) were analyzed using one-way ANOVA and Tukeys test (α∗= 0.05). Two-parameter Weibull distribution values including the Weibull modulus, scale (m), and shape (0) values were calculated. Mean MTBS results (MPa) showed significant difference between the experimental groups (p = 0.001) and were in descending order as follows: C1-CC (32.8 ±∗6.4)a <∗C1 (24.4 ±∗5.2)b <∗C2 (21.1 ±∗4.8)b <∗C1-APF (19.3 ±∗4.4)b <∗C2-CC (14.1 ±∗4.1)c <∗C2-APF (8.1 ±∗2.1)d. C1 and C2 presented non-significant bond strength of the resin composite bonded with SBU (p >∗0.05). CC application significantly increased the bond strength in TE mode, but significant reduction was observed when used in SE mode (p <∗0.05). The use of APF did not significantly decrease the bond strength in TE mode, but significant reduction was observed when used in SE mode. Considering Weibull parameters, characteristics of adhesion seem to be less reliable for C2-CC (m = 3.86) and more reliable for C1-CC (m = 6.77). Failure types were predominantly adhesive between the dentin and the adhesive resin. Mixed failures were more common for both C1 and C2 and total etch-CC combination.
YÖKSİS Kayıtları
Does 2 chlorhexidine digluconate cavity disinfectant or sodium fluoride hydroxyethyl methacrylate affect adhesion of universal adhesive to dentin
Journal of Adhesion Science and Technology · 2015 SSCI
Prof. Dr. ALİ RIZA ÇETİN →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 20 kaydı bulundu.
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 20 kaydı bulundu.
Are dentin posts biomechanically intensive A laboratory and FEA study
2014 ISSN: 0169-4243 SSCI
Prof. Dr. OĞUZ ERASLAN →
Does 2 chlorhexidine digluconate cavity disinfectant or sodium fluoride hydroxyethyl methacrylate affect adhesion of universal adhesive to dentin
2015 ISSN: 0169-4243 SSCI
Prof. Dr. ALİ RIZA ÇETİN →
Functionalization of polystyrene and adhesion studies
1997 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. AHMET OKUDAN →
Effects of the functional groups of polystyrene on its adhesion improvement and corrosion resistance
1998 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. AHMET OKUDAN →
Response of exposed human pulp to application of a hemostatic agent and a self etch adhesive
2015 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. ÖZGÜR ÖZDEMİR →
Adhesion and corrosion resistance properties of coatings obtained from modified low molecular weight polystyrenes
2006 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. AHMET KOÇAK →
Response of exposed human pulp to application of a hemostatic agent and a self etch adhesive
2015 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. NEVİN ÇOBANOĞLU →
POLYTETRAFLUOROETYLENE TAPE AS TEMPORARY RESTORATIVEMATERIAL A FLUID FILTRATION STUDY
2015 ISSN: 0169-4243 Endekste taranmıyor
Prof. Dr. SEMA BELLİ →
Which is effective on bond strength of resin based sealers incorporation of powdered dentin to primer or adhesive
2015 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. SEMA BELLİ →
Effect of 2 chlorhexidine gluconate cavity disinfectant on microtensile bond strength of tooth coloured restorative materials to sound and caries affected dentin
2015 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. SEMA BELLİ →
The effect of different restoration techniques on fracture strength of teeth with flared roots
2014 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. SEMA BELLİ →
Functionalization of polystyrene and adhesion studies
1997 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. ERSİN GÜLER →
Effect of intracanal medicaments on the push out bond strength of Biodentine in comparison with Bioaggregate apical plugs
2015 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. AYÇE ÜNVERDİ →
Comparison of the mechanical and biological properties of self adhering materials
2016 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. HAYRİYE ESRA ÜLKER →
The effects of water flow rate on shear bond strength of self etch resin cement to dentin surface after Er,Cr:YSGG laser etching
2017 ISSN: 0169-4243 SCI
Prof. Dr. İSA YÖNDEM →
Comparison of the mechanical and biological properties of self-adhering materials
2016 ISSN: 0169-4243 SCI-Expanded Q3
Doç. Dr. FİRDEVS KAHVECİOĞLU →
Residual monomer release from orthodontic adhesives cured with different light sources
2016 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. MURAT SELİM BOTSALI →
Effect of post restoration on stresses in premolars with endodontic periodontal lesion an FEA study
2017 ISSN: 0169-4243 SCI-Expanded
Prof. Dr. OĞUZ ERASLAN →
Shear bond strength to enamel and failure type of different periodontal splints :in vivo and in vitro study
2016 ISSN: 0169-4243 SCI-Expanded Q3
Doç. Dr. MERVE GÜRSES →
The effects of water flow rate on shear bond strength of self etch resin cement to dentin surface after Er Cr YSGG laser etching
2016 ISSN: 0169-4243 SSCI
Prof. Dr. İSA YÖNDEM →
Makale Bilgileri
Toplam Atıf
7 atıf
· Scopus
ISSN01694243
Yayın TarihiOcak 2016
Cilt / Sayfa30 · 13-23
Scopus ID2-s2.0-84946498306
Kurumlar
İstanbul Medipol Üniversitesi
Istanbul Turkey
Selçuk Üniversitesi
Selçuklu Turkey
Universität Zürich
Zurich Switzerland
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 7.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi (ISSN Eşleşmesi)
Journal of Adhesion Science and Technology
Q2
SJR Skoru0,548
H-Index92
YayıncıTaylor and Francis Ltd.
ÜlkeUnited Kingdom
Chemistry (miscellaneous) (Q2)
Materials Chemistry (Q2)
Mechanics of Materials (Q2)
Surfaces and Interfaces (Q2)
Surfaces, Coatings and Films (Q2)
Metrikler
7
Atıf