Scopus
🔓 Açık Erişim YÖKSİS ISSN Eşleşti
SJR Q4
Common Mistakes in the Dual-Energy X-ray Absorptiometry (DXA) in Turkey. A Retrospective Descriptive Multicenter Study
Acta Medica Hradec Kralove · Ocak 2016
Özet
BACKGROUND: Osteoporosis is a widespread metabolic bone disease representing a global public health problem currently affecting more than two hundred million people worldwide. The World Health Organization states that dual-energy X-ray absorptiometry (DXA) is the best densitometric technique for assessing bone mineral density (BMD). DXA provides an accurate diagnosis of osteoporosis, a good estimation of fracture risk, and is a useful tool for monitoring patients undergoing treatment. Common mistakes in BMD testing can be divided into four principal categories: 1) indication errors, 2) lack of quality control and calibration, 3) analysis and interpretation errors, and 4) inappropriate acquisition techniques. The aim of this retrospective multicenter descriptive study is to identify the common errors in the application of the DXA technique in Turkey. METHODS: All DXA scans performed during the observation period were included in the study if the measurements of both, the lumbar spine and proximal femur were recorded. Forearm measurement, total body measurements, and measurements performed on children were excluded. Each examination was surveyed by 30 consultants from 20 different centers each informed and trained in the principles of and the standards for DXA scanning before the study. RESULTS: A total of 3,212 DXA scan results from 20 different centers in 15 different Turkish cities were collected. The percentage of the discovered erroneous measurements varied from 10.5% to 65.5% in the lumbar spine and from 21.3% to 74.2% in the proximal femur. The overall error rate was found to be 31.8% (n = 1021) for the lumbar spine and 49.0% (n = 1576) for the proximal femur. CONCLUSION: In Turkey, DXA measurements of BMD have been in use for over 20 years, and examination processes continue to improve. There is no educational standard for operator training, and a lack of knowledge can lead to significant errors in the acquisition, analysis, and interpretation.
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 3 kaydı bulundu.
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 3 kaydı bulundu.
Common Mistakes in the Dual-Energy X-ray Absorptiometry (DXA) in Turkey. A Retrospective Descriptive Multicenter Study
2016 ISSN: 1211-4286 IM: Index Medicus
Doç. Dr. KEMAL EROL →
Triglycerides Predict Plasma Fibronectin in Children with Type I Diabetes Mellitus Rather than Diabetes
2002 ISSN: 1211-4286 SCOPUS
Doç. Dr. RAMAZAN KOCABAŞ →
Diagnostic Value of C-Reactive Protein in Patients with Angiographically Documented Coronary Heart Disease
2002 ISSN: 1211-4286 SCOPUS
Doç. Dr. RAMAZAN KOCABAŞ →
Makale Bilgileri
Toplam Atıf
15 atıf
· Scopus
ISSN12114286
Yayın TarihiOcak 2016
Cilt / Sayfa59 · 117-123
Scopus ID2-s2.0-85021857776
Erişim🔓 Açık Erişim
Kurumlar
Akdeniz University, Faculty of Medicine
Antalya Turkey
Konya Beyhekim State Hospital
Konya Turkey
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 15.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi (ISSN Eşleşmesi)
Acta Medica
Q4
OA
SJR Skoru0,188
H-Index34
YayıncıCharles University Faculty of Medicine in Hradec Kralove
ÜlkeCzech Republic
Medicine (miscellaneous) (Q4)
Metrikler
15
Atıf