Scopus
YÖKSİS DOI Eşleşti
SJR Q1
Survey of CT radiation doses and iodinated contrast medium administration: an international multicentric study
European Radiology · Nisan 2025
Özet
Objective: To assess the relationship between intravenous iodinated contrast media (ICM) administration usage and radiation doses for contrast-enhanced (CE) CT of head, chest, and abdomen–pelvis (AP) in international, multicenter settings. Methods: Our international (n = 16 countries), multicenter (n = 43 sites), and cross-sectional (ConRad) study had two parts. Part 1: Redcap survey with questions on information related to CT and ICM manufacturer/brand and respective protocols. Part 2: Information on 3,258 patients (18–96 years; M:F 1654:1604) who underwent CECT for a routine head (n = 456), chest (n = 528), AP (n = 599), head CT angiography (n = 539), pulmonary embolism (n = 599), and liver CT examinations (n = 537) at 43 sites across five continents. The following information was recorded: hospital name, patient age, gender, body mass index [BMI], clinical indications, scan parameters (number of scan phases, kV), IV-contrast information (concentration, volume, flow rate, and delay), and dose indices (CTDIvol and DLP). Results: Most routine chest (58.4%) and AP (68.7%) CECT exams were performed with 2–4 scan phases with fixed scan delay (chest 71.4%; AP 79.8%, liver CECT 50.7%) following ICM administration. Most sites did not change kV across different patients and scan phases; most CECT protocols were performed at 120–140 kV (83%, 1979/2685). There were no significant differences between radiation doses for non-contrast (CTDIvol 24 [16–30] mGy; DLP 633 [414–702] mGy·cm) and post-contrast phases (22 [19–27] mGy; 648 [392–694] mGy·cm) (p = 0.142). Sites that used bolus tracking for chest and AP CECT had lower CTDIvol than sites with fixed scan delays (p < 0.001). There was no correlation between BMI and CTDIvol (r2 ≤ − 0.1 to 0.1, p = 0.931). Conclusion: Our study demonstrates up to ten-fold variability in ICM injection protocols and radiation doses across different CT protocols. The study emphasizes the need for optimizing CT scanning and contrast protocols to reduce unnecessary contrast and radiation exposure to patients. Clinical relevance statement: The wide variability and lack of standardization of ICM media and radiation doses in CT protocols suggest the need for education and optimization of contrast usage and scan factors for optimizing image quality in CECT. Key Points: There is a lack of patient-centric CT protocol optimization taking into consideration mainly patients’ size. There is a lack of correlation between ICM volume and CT radiation dose across CT protocol. A ten-fold variation in iodine-load for the same CT protocol in sites suggests a lack of standardization.
YÖKSİS Kayıtları
Survey of CT radiation doses and iodinated contrast medium administration: an international multicentric study
European Radiology · 2024 SCI-Expanded
Doç. Dr. ABİDİN KILINÇER →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 6 kaydı bulundu.
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 6 kaydı bulundu.
Congenital infiltrating lipomatosis of the face with cerebral abnormalities
2000 ISSN: 0938-7994 SCI
Prof. Dr. NEVZAT SERDAR UĞRAŞ →
A new technique for the diagnosis of acute appendicitis: abdominal CT with compression to the right lower quadrant
2017 ISSN: 0938-7994 SCI-Expanded Q1
Doç. Dr. ABİDİN KILINÇER →
Assessment of Lacrimal Gland Involvement in Primary Sjögren’s Syndrome Using Gray scale Ultrasonography and Shear Wave Elastography
2023 ISSN: 0938-7994 SCI-Expanded
Prof. Dr. SEMA YILMAZ →
Assessment of lacrimal gland involvement in primary Sjögren’s syndrome using gray-scale ultrasonography and shear wave elastography
2023 ISSN: 0938-7994 SCI-Expanded Q1
Prof. Dr. BANU BOZKURT →
Assessment of lacrimal gland involvement in primary Sjögren’s syndrome using gray-scale ultrasonography and shear wave elastography
2023 ISSN: 0938-7994 SCI-Expanded Q1
Doç. Dr. HALİL ÖZER →
Assessment of lacrimal gland involvement in primary Sjögren’s
syndrome using gray‑scale ultrasonography and shear wave
elastography
2023 ISSN: 0938-7994 SCI-Expanded Q1
Prof. Dr. MEHMET SEDAT DURMAZ →
Makale Bilgileri
Dergi
European Radiology
Toplam Atıf
10 atıf
· Scopus
ISSN09387994
Yayın TarihiNisan 2025
Cilt / Sayfa35 · 1915-1932
Scopus ID2-s2.0-85202010223
Kurumlar
Ahmadu Bello University
Zaria Nigeria
Ain Shams University
Cairo Egypt
Al-Kindi Hospital
Amman Jordan
All India Institute of Medical Sciences, New Delhi
New Delhi India
American University of Beirut
Beirut Lebanon
Amman Arab University
Amman Jordan
An-Najah National University
Nablus Palestine
Bangalore Medical College and Research Institute
Bengaluru India
Bridgeport Hospital
Bridgeport United States
Burjeel Hospital
Dubai United Arab Emirates
Bushehr University of Medical Sciences
Bushehr Iran
Fr. Muller Medical College Hospital
Mangalore India
GMERS Medical College, Gandhinagar
Gandhinagar India
Hamadan University of Medical Sciences
Hamadan Iran
Hamad General Hospital
Doha Qatar
Hospital de Clinicas
Sao Paulo Brazil
Hospital Sirio-Libanês
Sao Paulo Brazil
Hospital Universitario Dr. Jose Eleuterio Gonzalez
Monterrey Mexico
Hospital Zambrano Hellion TecSalud
San Pedro Garza Garcia Mexico
Icahn School of Medicine at Mount Sinai
New York United States
Institut de Cardiologie de l'Université d'Ottawa
Ottawa Canada
Institute Nacional De Ciencias
México Brazil
Instituto de Ciencias Médicas: Instituto de Ciencias Medica
Alicante Panama
International Atomic Energy Agency, Vienna
Vienna Austria
Isfahan University of Medical Sciences
Isfahan Iran
Isra University
Hyderabad Pakistan
Jordan University of Science and Technology
Irbid Jordan
Kashan University of Medical Sciences
Kashan Iran
Kerman University of Medical Sciences
Kerman Iran
King Abdulaziz University Hospital
Jeddah Saudi Arabia
King Abdullah University Hospital
Irbid Jordan
King George's Medical University
Lucknow India
King Hussein Cancer Center
Amman Jordan
Klinički Bolnički Centar Rijeka
Rijeka Croatia
Lagos University Teaching Hospital
Lagos Nigeria
Lebanese International University
Beirut Lebanon
Massachusetts General Hospital
Boston United States
Mayo Clinic
Rochester United States
Nini Hospital
Tripoli Lebanon
Pontifícia Universidade Católica do Paraná
Curitiba Brazil
Rafik Hariri University Hospital
Beirut Lebanon
Sana'a University
Sana'a Yemen
Selçuk Üniversitesi
Selçuklu Turkey
Shahid Beheshti University of Medical Sciences
Tehran Iran
Shri Jagdishprasad Jhabarmal Tibrewala University
Jhunjhunu India
Smt. N.H.L. Municipal Medical College
Ahmedabad India
SRL Diagnostic Vadodara
Vadodara India
SUNY Upstate Medical University
Syracuse United States
The Maharaja Sayajirao University of Baroda
Vadodara India
Unimed do Brasil
Sao Paulo Brazil
Unimed Porto Alegre
Porto Alegre Brazil
Universidade Federal do Parana
Curitiba Brazil
Università degli Studi di Cagliari
Cagliari Italy
Université Ferhat Abbas Sétif 1
Setif Algeria
University of Central Florida
Orlando United States
University of Science and Technology (USTY)
Sana'a Yemen
Upendra Devkota Memorial National Institute of Neurological and Allied Sciences
Kathmandu Nepal
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 10.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi (ISSN Eşleşmesi)
European Radiology
Q1
OA
SJR Skoru1,724
H-Index191
YayıncıSpringer Science and Business Media Deutschland GmbH
ÜlkeGermany
Medicine (miscellaneous) (Q1)
Radiology, Nuclear Medicine and Imaging (Q1)
Metrikler
10
Atıf