Effect of scan repetition on the reproducibility of optic nerve head topographic measurements with the Top SS
Clinical and Experimental Ophthalmology · Nisan 2004
Özet
Purpose: To determine the effect of scan repetition during a single visit for improved reproducibility of optic nerve head topographic measurements. Methods: One randomly selected eye of 20 healthy subjects with no systemic or ocular disease was evaluated. Half of the subjects were under 30 years of age and the other half were older than 60 years. Five independent image series, each consisting of 10 newly recorded consecutive images, were obtained for each subject over a period of 10 weeks with a confocal scanning laser ophthalmoscope, the Top SS. Subjects were divided into two groups according to disc area being either smaller or larger than 2 mm2. Reproducibility of the measurements in three parameters (volume below, half depth area and the average depth) were calculated for each set of scans. The coefficient of variation (standard deviation divided by the mean) was taken as the measure of reproducibility. Repeated measures of analysis of variation and independent sample t-test were used for statistical analysis. Statistical significance was set as P < 0.05. Results: Both age groups were found to be equally distributed with respect to sex. There were no significant intergroup differences in keratometry, pupil diameter or refractive error. Increasing the scan repetition per visit up to five improved the reproducibility of the measurements. Further increases in scans per visit reduced the reproducibility. Subjects with larger discs and older age were found to have lower coefficients of variation for topographic measurements. Conclusions: Normal subjects should be examined at least three to four times per visit to have significantly improved reliability of measurements of optic nerve head topography. Factors associated with decreased reproducibility included older age, smaller discs, and more than five scans per visit. Sex, refraction and pupil diameter were shown to have no effect on the reproducibility.
YÖKSİS Kayıtları
Effect of scan repetition on the reproducibility of optic nerve head topographic measurements with the Top SS
Clinical and Experimental Ophthalmology · 2004 SCI
Prof. Dr. BANU BOZKURT →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 5 kaydı bulundu.
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 5 kaydı bulundu.
Association of tumour necrosis factor alpha 308 G A polymorphism with primary open angle glaucoma
2012 ISSN: 1442-6404 SCI-Expanded
Prof. Dr. BANU BOZKURT →
In vivo confocal microscopy in a patient with conjunctival amyloidosis
2008 ISSN: 1442-6404 SCI
Prof. Dr. BANU BOZKURT →
Immunohistochemical findings in prosthesis associated giant papillary conjunctivitis
2007 ISSN: 1442-6404 SCI-Expanded
Prof. Dr. BANU BOZKURT →
Effect of scan repetition on the reproducibility of optic nerve head topographic measurements with the Top SS
2004 ISSN: 1442-6404 SCI
Prof. Dr. BANU BOZKURT →
Effects of topical antiglaucoma drugs on apoptosis rates of conjunctival epithelial cells in glaucoma patients
2004 ISSN: 1442-6404 SSCI
Prof. Dr. BANU BOZKURT →
Makale Bilgileri
Toplam Atıf
0 atıf
· Scopus
ISSN14426404
Yayın TarihiNisan 2004
Cilt / Sayfa32 · 142-146
Scopus ID2-s2.0-2442436860
Kurumlar
Akdeniz Üniversitesi
Antalya Turkey
Hacettepe Üniversitesi
Ankara Turkey
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi (ISSN Eşleşmesi)
Clinical and Experimental Ophthalmology
Q1
SJR Skoru1,941
H-Index99
YayıncıWiley-Blackwell Publishing Ltd
ÜlkeUnited Kingdom
Medicine (miscellaneous) (Q1)
Ophthalmology (Q1)