Scopus
YÖKSİS DOI Eşleşti
SJR Q1
Relationship between Humphrey 30-2 SITA standard test, matrix 30-2 threshold test, and Heidelberg Retina Tomograph in ocular hypertensive and glaucoma patients
Journal of Glaucoma · Ocak 2008
Özet
PURPOSE: To evaluate the relationship between global indices of Humphrey standard automated perimetry (SAP, 30-2 SITA standard test), Humphrey Matrix frequency doubling technology (FDT, 30-2 threshold test), and Heidelberg Retina Tomograph (HRT II) parameters and measure the level of agreement among these 3 tests in classifying eyes as normal or abnormal. METHODS: The study included 1 eye of 29 ocular hypertensive and 56 glaucoma patients with a mean age of 60.9±10.5 years. All subjects had reliable visual fields and HRT measurements performed within a 2-week period. The eyes were classified as normal/abnormal according to visual field criteria and Moorfields regression analysis (MRA). Correlations between visual field indices (mean deviation and pattern standard deviation) and HRT parameters were analyzed using Spearman correlation coefficient (r) and the agreement between the tests in classifying eyes was defined with κ value. RESULTS: FDT Matrix mean deviation and pattern standard deviation parameters were found to be highly correlated with those of SAP (r=0.66 and 0.69, respectively). Visual field indices showed statistically significant correlations with cup area, rim area, cup/disc (C/D) area, linear C/D, cup shape, mean retinal nerve fiber layer thickness and retinal nerve fiber layer area parameters (P<0.05). Fifty-eight patients (68.2%) had abnormal results at least with 1 of the tests and 21 subjects (24.7%) had abnormal results with all 3 tests. The κ values were 0.6 for SAP and Matrix (P<0.001), 0.33 for SAP and MRA (P=0.002), and 0.31 for Matrix and MRA (P=0.004). CONCLUSIONS: FDT Matrix results are highly comparable with SAP in the assessment of glaucoma. Visual field global indices show statistically significant, but low-moderate correlations with most of the HRT parameters. The agreement among MRA and visual fields for abnormality is fair. Either HRT or visual fields may show the first evidence of glaucomatous damage; therefore, the combination of optic nerve head parameters and visual field results could improve glaucoma diagnosis and follow-up. © 2008 Lippincott Williams & Wilkins, Inc.
YÖKSİS Kayıtları
Relationship Between Humphrey 30 2 SITA Standard Test Matrix 30 2 Threshold Test and Heidelberg Retina Tomograph in Ocular Hypertensive and Glaucoma Patients
JOURNAL OF GLAUCOMA · 2008 SCI-Expanded
Prof. Dr. BANU BOZKURT →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 1 kaydı bulundu.
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 1 kaydı bulundu.
Relationship Between Humphrey 30 2 SITA Standard Test Matrix 30 2 Threshold Test and Heidelberg Retina Tomograph in Ocular Hypertensive and Glaucoma Patients
2008 ISSN: 1057-0829 SCI-Expanded
Prof. Dr. BANU BOZKURT →
Makale Bilgileri
Dergi
Journal of Glaucoma
Toplam Atıf
15 atıf
· Scopus
ISSN10570829
Yayın TarihiOcak 2008
Cilt / Sayfa17 · 203-210
Scopus ID2-s2.0-42149087004
Kurumlar
Hacettepe Üniversitesi
Ankara Turkey
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 15.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi (ISSN Eşleşmesi)
Journal of Glaucoma
Q1
SJR Skoru0,973
H-Index109
YayıncıLippincott Williams and Wilkins
ÜlkeUnited States
Ophthalmology (Q1)
Metrikler
15
Atıf