Comparison of the CoaguChek XS handheld coagulation analyzer and conventional laboratory methods measuring international normalised ratio (INR) values during the time to therapeutic range after mechanical valve surgery

Journal of Cardiac Surgery · Mayıs 2013

Özet
Aim: To compare the international normalised ratio (INR) value of patients evaluated using the CoaguChek XS versus conventional laboratory methods, in the period after open-heart surgery for mechanical valve replacement until a therapeutic range is achieved using vitamin K antagonists (VKA) together with low molecular weight heparin (LMWH). Methods: One hundred and five patients undergoing open-heart surgery for mechanical valve replacement were enrolled. Blood samples were collected from patients before surgery, and on the second and fifth postoperative days, simultaneously for both the point of care device and conventional laboratory techniques. Patients were administered VKA together with LMWH at therapeutic doses (enoxaparin 100 IU/kg twice daily) subcutaneously, until an effective range was achieved on approximately the fifth day after surgery. Results: The mean INR values using the CoaguChek XS preoperatively and on the second and fifth days postoperatively were 1.20 (SD ± 0.09), 1.82 (SD ± 0.45), and 2.55 (SD ± 0.55), respectively. Corresponding results obtained using conventional laboratory techniques were 1.18 (SD ± 0.1), 1.81 (SD ± 0.43), and 2.51 (SD ± 0.58). The correlation coefficient was r = 0.77 preoperatively, r = 0.981 on postoperative day 2, and r = 0.983 on postoperative day 5. Discussion: Results using the CoaguChek XS Handheld Coagulation Analyzer correlated strongly with conventional laboratory methods, in the bridging period between open-heart surgery for mechanical valve replacement and the achievement of a therapeutic range on warfarin and LMWH. © 2013 Wiley Periodicals, Inc.
7 atıf Mayıs 2013 DOI
YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
Comparison of the CoaguChek XS Handheld Coagulation Analyzer and Conventional Laboratory Methods Measuring International Normalised Ratio (INR) Values during the Time to Therapeutic Range after Mechanical Valve Surgery
Journal of Cardiac Surgery · 2013 SCI-Expanded
Doç. Dr. ÖMER FARUK ÇİÇEK →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 1 kaydı bulundu.
Comparison of the CoaguChek XS Handheld Coagulation Analyzer and Conventional Laboratory Methods Measuring International Normalised Ratio (INR) Values during the Time to Therapeutic Range after Mechanical Valve Surgery
2013 ISSN: 0886-0440 SCI-Expanded Q4
Doç. Dr. ÖMER FARUK ÇİÇEK →

Makale Bilgileri

Toplam Atıf 7 atıf · Scopus
ISSN08860440
Yayın TarihiMayıs 2013
Cilt / Sayfa28 · 254-257

Kurumlar

Turkiye Yuksek Ihtisas Hospital
Ankara Turkey

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 7.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi (ISSN Eşleşmesi)
Journal of Cardiac Surgery
Q2
SJR Skoru0,413
H-Index71
YayıncıJohn Wiley and Sons Inc
ÜlkeUnited States
Surgery (Q2)
Cardiology and Cardiovascular Medicine (Q3)
Pulmonary and Respiratory Medicine (Q3)
Dergi sayfasına git

Metrikler

7
Atıf

Sistemimizdeki Yazarlar