CANLI
Yükleniyor Veriler getiriliyor…
/ Makaleler / Scopus Detay
Scopus YÖKSİS DOI Eşleşti SJR Q3

Amperometric xanthine biosensors based on electrodeposition of platinum on polyvinylferrocenium coated Pt electrode

Journal of Molecular Catalysis B Enzymatic · Kasım 2011

Özet
Novel xanthine biosensors were successfully fabricated by immobilizing xanthine oxidase on polyvinylferrocenium perchlorate matrix (PVF +ClO4-) and platinum electrodeposited polyvinylferrocenium perchlorate matrix. PVF+ClO4 - film was coated on Pt electrode at +0.7 V vs. Ag/AgCl by electrooxidation of polyvinylferrocene (PVF). Platinum nanoparticles were deposited on PVF+ClO4- electrode by electrochemical deposition in 2.0 mM H2PtCl6 solution at -0.2 V. Xanthine oxidase was incorporated into the polymer matrix via ion exchange process by immersing modified Pt electrodes in the enzyme solution. The amperometric responses of the biosensors were measured via monitoring oxidation current of hydrogen peroxide at +0.5 V. Under the optimal conditions, the linear ranges of xanthine detection were determined as 1.73 × 10 -3-1.74 mM for PVF+XO- and 0.43 × 10 -3-2.84 mM for PVF+XO-/Pt. The detection limits of xanthine were 5.20 × 10-4 mM for PVF+XO - and 1.30 × 10-4 mM for PVF+XO -/Pt. Moreover, the effects of applied potential, electrodeposition potential, H2PtCl6 concentration, amount of electrodeposited Pt nanoparticles, thickness of polymeric film, temperature, immobilization time, xanthine and xanthine oxidase concentrations on the response currents of the biosensors were investigated in detail. The effects of interferents, the operational and storage stabilities of biosensors and the applicabilities to drug samples of the biosensors analysis were also evaluated. © 2011 Elsevier B.V.
27 atıf Kasım 2011 DOI
YÖKSİS DOI Eşleşmesi Bulundu

Bu Scopus makalesi YÖKSİS veritabanında da kayıtlı. Aşağıda YÖKSİS verilerini görebilirsiniz.

YÖKSİS Kayıtları
Amperometric xanthine biosensors based on electrodeposition of platinum on polyvinylferrocenium coated Pt electrode
Journal of Molecular Catalysis B: Enzymatic · 2011 SCI-Expanded
Prof. Dr. SALİH ZEKİ BAŞ →
YÖKSİS Kayıtları — ISSN Eşleşmesi
Bu dergide (ISSN eşleşmesi) kurumun 5 kaydı bulundu.
Amperometric xanthine biosensors based on electrodeposition of platinum on polyvinylferrocenium coated Pt electrode
2011 ISSN: 13811177 SCI-Expanded
Prof. Dr. SALİH ZEKİ BAŞ →
Synthesis of calix n arene based silica polymers for lipase immobilization
2009 ISSN: 13811177 SCI-Expanded
Prof. Dr. SERKAN ERDEMİR →
Immobilization of Candida rugosa lipase on magnetic sol gel composite supports for enzymatic resolution of R S Naproxen methyl ester
2011 ISSN: 13811177 SCI-Expanded
Prof. Dr. ELİF ÖZYILMAZ →
Enantioselective hydrolysis of rasemic naproxen methyl ester with sol gel encapsulated lipase in the presence of sporopollenin
2010 ISSN: 13811177 SCI-Expanded
Prof. Dr. ELİF ÖZYILMAZ →
Synthesis and characterization of cyclodextrin based polymers as a support for immobilization of Candida rugosa lipase
2009 ISSN: 13811177 SCI-Expanded
Prof. Dr. ELİF ÖZYILMAZ →

Makale Bilgileri

Toplam Atıf 27 atıf · Scopus
ISSN13811177
Yayın TarihiKasım 2011
Cilt / Sayfa72 · 282-288

Kurumlar

Selçuk Üniversitesi
Selçuklu Turkey

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 27.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi (ISSN Eşleşmesi)
Journal of Molecular Catalysis - B Enzymatic
Q3
SJR Skoru0,324
H-Index111
YayıncıElsevier
ÜlkeNetherlands
Bioengineering (Q3)
Process Chemistry and Technology (Q3)
Biochemistry (Q4)
Catalysis (Q4)
Dergi sayfasına git

Metrikler

27
Atıf

Sistemimizdeki Yazarlar