CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded JCR Q2 Vaka Takdimi Scopus
Long-Term Monitoring of an Intracorneal Bee Stinger Using Anterior Segment Optical Coherence Tomography and In Vivo Confocal Microscopy
Eye & Contact Lens-Science and Clinical Practice 2026 Cilt 52 Sayı 1
Scopus Eşleşmesi Bulundu
0
Atıf
52
Cilt
39-44
Sayfa
Özet
Abstract: – A 19-year-old male patient presented to our clinic with complaints of foreign-body sensation, pain, redness, tearing, and decreased vision in the right eye. One day prior, a bee struck his eye while he was riding a motorcycle. Biomicroscopic examination of the right eye showed periorbital edema, chemosis, ciliary injection, corneal edema with radiating Descemet folds, paracentral corneal infiltrate, and a brown needle-like foreign body resembling a bee stinger. Anterior segment optical coherence tomography (AS-OCT) confirmed corneal edema with Descemet folds, whereas in vivo confocal microscopy (IVCM) revealed multiple hyporeflective, round cyst-like structures within the superficial corneal epithelium, hyperreflective, round inflammatory cells around the subbasal nerves, a honeycomb pattern, and a hyperreflective, needle-like linear opacity in the stroma. The patient was treated with topical moxifloxacin 0.5%, dexamethasone 0.1%, and fluconazole 0.2% eye drops and oral moxifloxacin (400 mg) and cetirizine (10 mg) tablets. The patient's signs and symptoms improved significantly within 1 week. At the 18-month examination, the patient's vision was 20/20, with only a faint stromal opacity remaining. No stinger fragments were detected on biomicroscopic examination, AS-OCT, or IVCM examination. Anterior segment optical coherence tomography and IVCM are highly valuable for monitoring corneal edema, inflammation, cellular changes, and the embedded stinger within the cornea throughout the follow-up period.
Web of Science Eşleşmesi Bulundu
0
WoS Atıf
52
Cilt
Article
Belge Türü
Kaynak: EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE · s. 39-44
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.

Anahtar Kelimeler

WoS | Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.

Makale Bilgileri

Dergi Eye & Contact Lens-Science and Clinical Practice
ISSN 1542-2321
Yıl 2026 / 1. ay
Cilt / Sayı 52 / 1
Sayfalar 39 – 44
Makale Türü Vaka Takdimi
Hakemlik Hakemli
Endeks SCI-Expanded
JCR Quartile Q2
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 4 kişi
Erişim Türü Elektronik
Alan Sağlık Bilimleri Temel Alanı Göz Hastalıkları

YÖKSİS Yazar Kaydı

Yazar Adı BOZKURT BANU,HUSEYNLI NİJAT,BOZKURT OFLAZ AYŞE,EVREN KEMER ÖZLEM
YÖKSİS ID 8990930