Scopus Eşleşmesi Bulundu
1
Atıf
45
Cilt
1591-1596
Sayfa
Özet
Purpose: Stereopsis, a critical aspect of binocular vision, can be influenced by refractive errors. This study investigated how experimentally induced anisometropia affected distance stereopsis in adults and aimed to determine threshold levels for different types and amounts of experimentally induced anisometropia. Methods: Twenty healthy adults (aged 20–45 years) with normal visual acuity and baseline distance stereopsis were included. Distance stereopsis was assessed using the Distance Randot Stereotest at 3 m. Trial lenses inducing myopic, hyperopic and astigmatic anisometropia (axes: 45°, 90° and 180°) were applied over the dominant eye in 0.25 D increments. After each lens placement, a 30-s adaptation period preceded assessment of stereoacuity. At each disparity level (400, 200, 100 and 60 arc seconds), the minimum anisometropic lens power causing loss of stereoacuity was recorded. As per the test manual, each disparity level included plates A and B, but only B plate responses were analysed, as correct identification was required to proceed. Results: Experimentally induced myopic anisometropia led to the earliest loss of stereopsis, with a mean threshold of 1.38 D at the 400 arc seconds level. Against-the-rule astigmatism exhibited the greatest tolerance, requiring higher refractive errors to degrade stereoacuity (p < 0.001). At 400 and 200 arc seconds, even low levels of experimentally induced myopic anisometropia (<0.50 D) impaired stereopsis significantly (p < 0.001), whereas against-the-rule astigmatism did not affect stereopsis significantly until higher anisometropia levels were induced (60 and 100 arc seconds). Conclusions: Even low levels of experimentally induced myopic anisometropia may disrupt distance stereopsis in visually normal adults. These findings may highlight consideration of a precise refractive correction in the presence of anisometropia to optimise distance stereopsis.
Web of Science Eşleşmesi Bulundu
1
WoS Atıf
45
Cilt
Article
Belge Türü
Kaynak: OPHTHALMIC AND PHYSIOLOGICAL OPTICS
· s. 1591-1596
Anahtar Kelimeler (WoS)
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 1.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi
Otomatik ISSN Eşleştirmesi
2025 yılı verileri
Ophthalmic and Physiological Optics
Q1
SJR Quartile
1,117
SJR Skoru
93
H-Index
Kategoriler: Ophthalmology (Q1) · Optometry (Q1) · Sensory Systems (Q1)
Alanlar: Health Professions · Medicine · Neuroscience
Ülke: United Kingdom
· Springer Nature
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir.
Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.
Anahtar Kelimeler
anisometropia
binocular vision
distance stereopsis
myopic anisometropia
refractive errors
stereoacuity
WoS |
Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.
Makale Bilgileri
Dergi
Ophthalmic and Physiological Optics
ISSN
0275-5408
Yıl
2025
/ 11. ay
Cilt / Sayı
45
/ 7
Sayfalar
1591 – 1596
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SCI-Expanded
JCR Quartile
Q2
Yayın Dili
İngilizce
Kapsam
Uluslararası
Toplam Yazar
4 kişi
Erişim Türü
Elektronik
Alan
Sağlık Bilimleri Temel Alanı
Göz Hastalıkları
YÖKSİS Yazar Kaydı
Yazar Adı
TINKIR KAYITMAZBATIR EMİNE,ÜNAL ADEM,BOZKURT OFLAZ AYŞE,ACAR DUYAN ŞULE
YÖKSİS ID
8781529