Scopus Eşleşmesi Bulundu
3
Atıf
22
Cilt
2471-2490
Sayfa
Özet
Plug-in refrigerated display cabinets (RDCs) are widely used in supermarkets but consume a lot of energy. This study aims to increase the label class of RDCs by using a new generation microchannel condenser, a grooved evaporator, R449A, and R290 refrigerants as alternatives to R404A and implementing modifications to the system. The created systems were tested according to the ISO 23,953-2:2023 standard and characterized in detail for both eco-design and energy labeling criteria. The study showed that the heat exchange efficiency of the grooved tube evaporator was higher than that of the regular tube evaporator. However, a 30% higher pressure drop was measured for the grooved tube evaporator than for the smooth tube evaporator. Performance analysis of the developed refrigerators was performed from energy, economy, and environmental perspectives. The average coefficient of performance (COP) of the RDC was calculated as 2.4, and the second law efficiency of the RDC was determined to be 45.2%. When using the R290 + grooved evaporator combination, CO2 emissions were reduced by 22.74% per year as compared to the R404A + smooth evaporator. With an energy efficiency index (EEI) of 43.4, RDC’s energy class was upgraded from “E” to “D.” It was found that the compressor consumed 80.3% of the total energy consumption. The resistance, employed in condensation pans and accounting for 8.2% of the overall energy consumption, was discovered to be the second crucial factor affecting the energy class. The improvements and upgrades to RDC may strengthen the understanding of enhancing performance and serve as the foundation for future studies.
Web of Science Eşleşmesi Bulundu
3
WoS Atıf
22
Cilt
Article
Belge Türü
Kaynak: INTERNATIONAL JOURNAL OF GREEN ENERGY
· s. 2471-2490
Anahtar Kelimeler (WoS)
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 3.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi
Otomatik ISSN Eşleştirmesi
2025 yılı verileri
International Journal of Green Energy
Q2
SJR Quartile
0,652
SJR Skoru
64
H-Index
Kategoriler: Renewable Energy, Sustainability and the Environment (Q2)
Alanlar: Energy
Ülke: United States
· Taylor and Francis Ltd.
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir.
Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.
Anahtar Kelimeler
energy efficiency index
energy label
3E analysis
grooved tube evaporator
refrigerated display cabinet
WoS |
Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.
Makale Bilgileri
Dergi
International Journal of Green Energy
ISSN
1543-5075
Yıl
2025
/ 2. ay
Cilt / Sayı
22
/ 12
Sayfalar
2471 – 2490
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SCI-Expanded
JCR Quartile
Q2
Teşvik Puanı
2,40
· YÖKSİS Akademik Teşvik
Yayın Dili
İngilizce
Kapsam
Uluslararası
Toplam Yazar
6 kişi
Erişim Türü
Basılı+Elektronik
Alan
Mühendislik Temel Alanı
Makine Mühendisliği
Enerji
YÖKSİS Yazar Kaydı
Yazar Adı
DEMİRPOLAT HAVVA,ERTEN Süleyman,AKTAŞ MUSTAFA,Ermişler Nureddin,Kodakoğlu Furkan,ŞEVİK SEYFİ
YÖKSİS ID
8528365