Scopus Eşleşmesi Bulundu
10
Atıf
88
Cilt
125-130
Sayfa
Özet
Purpose: This study aimed to evaluate the diagnostic accuracy of Moorfields regression analysis (MRA) and the glaucoma probability score (GPS) in primary open-angle glaucoma (POAG) and to measure the level of agreement between the two algorithms in classifying eyes as normal or abnormal in a Turkish population. Methods: We prospectively selected 184 healthy subjects and 158 subjects with POAG, who underwent an ophthalmological examination, visual field analysis and imaging with the Heidelberg Retina Tomograph II, using HRT III software, Version 3.0. The diagnostic accuracies of the two classifications were measured when the borderline was taken as either normal (highest specificity criteria) or abnormal (highest sensitivity criteria). The agreement between them was calculated using the unweighted kappa (κ) coefficient. Results: Optic nerve head topographic parameters showed statistically significant differences between the control and POAG groups (p < 0.001). The parameters with the highest area under the receiver operating characteristic curves were global GPS (0.86), cup : disc area (0.85), rim : disc area (0.85) and vertical cup : disc (0.85). According to the highest specificity criteria, MRA had a sensitivity of 67.7% and a specificity of 95.1%, whereas the GPS had a sensitivity of 70.9% and a specificity of 88.0%. According to the highest sensitivity criteria, MRA had a sensitivity of 81.0% and a specificity of 75.0%, whereas the GPS had a sensitivity of 89.2% and a specificity of 57.6%. A moderate agreement of 68% (233 eyes) with a κ coefficient of 0.51 was found between MRA and the GPS. Conclusions: The GPS automated classification showed similar sensitivity to MRA, but considerably lower specificity, when applied in a Turkish population. © 2009 Acta Ophthalmol.
Web of Science Eşleşmesi Bulundu
9
WoS Atıf
88
Cilt
Article
Belge Türü
Kaynak: ACTA OPHTHALMOLOGICA
· s. 125-130
Anahtar Kelimeler (WoS)
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 10.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi
Otomatik ISSN Eşleştirmesi
2010 yılı verileri
Acta Ophthalmologica
Q1
SJR Quartile
1,693
SJR Skoru
110
H-Index
🔓
Açık Erişim
Kategoriler: Medicine (miscellaneous) (Q1) · Ophthalmology (Q1)
Alanlar: Medicine
Ülke: United Kingdom
· John Wiley and Sons Inc
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir.
Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.
Anahtar Kelimeler
glaucoma
glaucoma probability score
Heidelberg Retina Tomograph (HRT) III
Moorfields regression analysis
Turkish population
WoS |
Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.
Makale Bilgileri
Dergi
ACTA OPHTHALMOLOGICA
ISSN
1755-375X
Yıl
2010
/ 2. ay
Cilt / Sayı
88
/ 1
Sayfalar
125 – 130
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SCI-Expanded
Yayın Dili
İngilizce
Kapsam
Uluslararası
Toplam Yazar
3 kişi
Erişim Türü
Elektronik
Alan
Sağlık Bilimleri Temel Alanı-
Göz Hastalıkları
YÖKSİS Yazar Kaydı
Yazar Adı
BOZKURT BANU,İRKEÇ MURAT TANJU,ARSLAN UMUT
YÖKSİS ID
1034326