SCI-Expanded
Özgün Makale
Scopus
Efficacy of additional lateral pinhole and SPECT/CT imaging in dual-phase Tc-99m MIBI parathyroid scintigraphy for localising parathyroid pathologies in patients with primary hyperparathyroidism: a single-institution experience
NUCLEAR MEDICINE COMMUNICATIONS
2025
Cilt 46
Sayı 1
Scopus Eşleşmesi Bulundu
0
Atıf
Özet
Purpose Parathyroid imaging with dual-phase technetium-99m methoxyisobutrylizonitrile (Tc-99m MIBI) scintigraphy serves as an important prerequisite for the identification of hyperfunctioning parathyroid gland(s) in patients with primary hyperparathyroidism (PHPT) for a successful targeted parathyroidectomy. This study aimed to evaluate the clinical value of additional lateral imaging and single-photon emission computed tomography/computed tomography (SPECT/CT) versus conventional planar imaging for locating parathyroid pathologies in patients with PHPT. Materials and methods A retrospective review was performed on 105 patients who underwent dual-phase Tc-99m MIBI scintigraphy and were surgically treated by parathyroidectomy. Dual-phase Tc-99m-MIBI planar scintigraphy with additional lateral pinhole views and SPECT/CT imaging was performed on a routine basis, as per departmental protocol. Comparison study between imaging modalities was done by patient-based analysis and scintigraphy results were compared with the clinical findings, biochemical markers, and histopathological findings. Results Sensitivity and specificity for anterior planar dual-phase Tc-99m MIBI scintigraphy were 78.8 and 80%, respectively. In comparison, lateral pinhole scan and SPECT/CT alone were found to have sensitivities of 85.9 and 90.9%, respectively, with the same specificity. Sensitivity decreased in patients with normocalcaemia and multiglandular disease. The mean adenoma weight and size for true-positive studies were significantly higher than those for false-negative or false-positive studies. Conclusion SPECT/CT provided the highest diagnostic accuracy for preoperative identification of parathyroid lesions in PHPT patients. Lateral pinhole imaging offers comparable sensitivity and aids in adenoma localisation when SPECT/CT is unavailable.
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi
Otomatik ISSN Eşleştirmesi
2025 yılı verileri
Nuclear Medicine Communications
Q3
SJR Quartile
0,399
SJR Skoru
84
H-Index
Kategoriler: Medicine (miscellaneous) (Q3) · Radiology, Nuclear Medicine and Imaging (Q3)
Alanlar: Medicine
Ülke: United Kingdom
· Wolters Kluwer Health
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir.
Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.
Anahtar Kelimeler
dual-phase parathyroid scintigraphy
lateral pinhole projection
primary hyperparathyroidism
sensitivity
SPECT/CT
YÖKSİS |
Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.
Makale Bilgileri
Dergi
NUCLEAR MEDICINE COMMUNICATIONS
ISSN
0143-3636
Yıl
2025
/ 1. ay
Cilt / Sayı
46
/ 1
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SCI-Expanded
Teşvik Puanı
0,28
· YÖKSİS Akademik Teşvik
Yayın Dili
İngilizce
Kapsam
Uluslararası
Toplam Yazar
16 kişi
Erişim Türü
Elektronik
Alan
Sağlık Bilimleri Temel Alanı
Nükleer Tıp
dual-phase parathyroid scintigraphy, lateral pinhole projection, primary hyperparathyroidism, sensitivity, SPECT/CT
YÖKSİS Yazar Kaydı
Yazar Adı
KESİM SELİN,TUROĞLU HALİL TURGUT,KÖTAN TUNCAY,BALABAN GENÇ ZEYNEP CEREN,NİFTALİYEVA KHANİM,TOPER MUHAMMED HASAN,YAVUZ DİLEK,ÖZGÜVEN SALİH,KAYA HANDAN,DEDE FUAT,UĞURLU MUSTAFA ÜMİT,ÖKSÜZOĞLU KEVSER,ÇAĞLIYAN FEYZA,GÜLLÜOĞLU MAHMUT BAHADIR,ÖNEŞ TUNÇ,ERDİL TANJU YUSUF
YÖKSİS ID
8316635