Background: The purpose of this study is to compare field-in-field radiotherapy (FIF) with conformal radiotherapy (CRT) in terms of dosimetric benefits for early stage endometrial cancer patients. Materials and methods: Ten consecutive early stage endometrial cancer patients who underwent adjuvant external beam radiotherapy were included in the study. For each patient, two different treatment plans were created. FIF and CRT plans were compared for doses in the planning target volume (PTV), the organ at risk (OAR) volumes including rectum, bladder, bowel, bilateral femurs and bone marrow, the dose homogeneity index, and the monitor unit counts required for the treatment. Results: The FIF technique significantly reduced the maximum dose of the PTV, rectum, bladder, bowel, left femur, right femur and bone marrow (p values were: <0.001, 0.031, 0.003, <0.001, 0.001, 0.001 and <0.001 respectively). When the OAR volumes irradiated with >30 and >45Gy were compared, the results were in favor of the FIF technique. The volumes of rectum, bladder, bowel, left femur, right femur and bone marrow receiving more than the prescription dose of 45Gy were significantly reduced with FIF technique (p values were 0.016, 0.039, 0.01, 0.04, 0.037 and 0.01 respectively). The dose homogeneity index (DHI) was significantly improved with FIF technique (p<0.001). Conclusions: FIF allowed more homogeneous dose distribution in the PTV and reduced the doses received by OAR. Considering the lower maximum doses in the OAR and PTV, FIF technique seems to be more advantageous than CRT during adjuvant radiotherapy for early stage endometrial cancer patients. © 2012 Associazione Italiana di Fisica Medica.

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 13.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2013 yılı verileri
Physica Medica
Q2
SJR Quartile
0,703
SJR Skoru
71
H-Index
Kategoriler: Biophysics (Q2) · Medicine (miscellaneous) (Q2) · Physics and Astronomy (miscellaneous) (Q2) · Radiology, Nuclear Medicine and Imaging (Q2)
Alanlar: Biochemistry, Genetics and Molecular Biology · Medicine · Physics and Astronomy
Ülke: Italy · Associazione Italiana di Fisica Medica
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

Bu makale için anahtar kelime bilgisi bulunmuyor.

Makale Bilgileri

Dergi Physica Medica
ISSN 11201797
Yıl 2013 / 11. ay
Cilt / Sayı 29 / 6
Sayfalar 577 – 582
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 8 kişi
Erişim Türü Elektronik
Alan Sağlık Bilimleri Temel Alanı- Kadın Hastalıkları ve Doğum

YÖKSİS Yazar Kaydı

Yazar Adı Yavas Guler, Yavas Cagdas, Acar Hilal, Buyukyoruk Ahmet, Cobanoglu Gokcen, Kerimoglu Ozlem Secilmis, Yavas Ozlem, Celik Cetin

Metrikler

Scopus Atıf 13
Havuz Atıfları 0
Yazar Sayısı 8