Özet
Purpose: This study investigated the effect of Hounsfield units (HU)-relative electron density (RED) calibration curves obtained with devices from three different Computed Tomography (CT) manufacturers on dose distribution in Accuray Precision planning of patients with lung cancer. Methods: All CT data required for treatment planning system (TPS) were obtained using the Tomotherapy 'cheese' phantom. HU RED calibration curves were created with images obtained from Siemens Somatom, GE Optima, and Toshiba Aquilion devices. The obtained calibration curve was extrapolated. CT images of lung cancer patients were acquired on a single device and treatment plans were created. The existing plans were recalculated using three calibration curves and the effect of the HU RED calibration curve on dose distribution was analyzed. Results: The results showed that different CTs did not produce significant dose differences in organ doses and PTV for Accuray TPS. Conclusions: Based on clinical judgment, images from different CT devices can be used in treatment planning.
Web of Science Eşleşmesi Bulundu
4
WoS Atıf
49
Cilt
Article
Belge Türü
Kaynak: JOURNAL OF MEDICAL PHYSICS
· s. 545-550
Anahtar Kelimeler (WoS)
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 4.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi
Otomatik ISSN Eşleştirmesi
2024 yılı verileri
Journal of Medical Physics
Q3
SJR Quartile
0,256
SJR Skoru
34
H-Index
🔓
Açık Erişim
Kategoriler: Radiology, Nuclear Medicine and Imaging (Q3) · Biophysics (Q4)
Alanlar: Biochemistry, Genetics and Molecular Biology · Medicine
Ülke: India
· Wolters Kluwer Medknow Publications
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir.
Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.
Anahtar Kelimeler
YÖKSİS WoS |
Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.
Makale Bilgileri
Dergi
Journal of Medical Physics
ISSN
0971-6203
Yıl
2024
/ 12. ay
Cilt / Sayı
49
/ 4
Sayfalar
545 – 550
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
ESCI
Teşvik Puanı
3,60
· YÖKSİS Akademik Teşvik
Yayın Dili
İngilizce
Kapsam
Uluslararası
Toplam Yazar
3 kişi
Erişim Türü
Basılı+Elektronik
Alan
Sağlık Bilimleri Temel Alanı
Sağlık Fiziği
Radyoterapi
YÖKSİS Yazar Kaydı
Yazar Adı
DEMİR HİKMETTİN,GÜL OSMAN VEFA,KANYILMAZ GÜL
YÖKSİS ID
8209968