CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded JCR Q1 Özgün Makale Scopus
Highly sensitive detection of Campylobacter jejuni using a carbon dot-embedded nanoMIPs fluorescent sensor
Microchemical Journal 2025 Cilt 208
Scopus Eşleşmesi Bulundu
8
Atıf
208
Cilt
🔓
Açık Erişim
Özet
Campylobacter jejuni, a leading cause of gastroenteritis worldwide, poses significant detection challenges due to the labor-intensive and insufficiently sensitive current methods. Developing efficient, rapid diagnostics is vital for clinical and food industry applications; yet the vulnerability of biological elements in creating bacterial sensors remains a major obstacle. This study introduces an innovative fluorescence-based sensor employing fully synthetic carbon dot (CDs) functionalized molecularly imprinted polymer (CDs@nanoMIPs) receptors to detect this foodborne pathogenic bacterium. The CDs@nanoMIPs synthesis was accomplished using a solid-phase approach, with an immunodominant epitope of C. jejuni serving as a guiding template. During the polymerization process, nitrogen-doped CDs were synthesized in situ and incorporated into nanoMIPs as a fluorescent tag, constituting approximately 19 % of the composite. The synthesized nanomaterials were characterized by employing transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), dynamic light scattering (DLS), Fourier-transform infrared spectroscopy (FT-IR), fluorescence microscopy, UV–Vis spectrophotometry, and fluorescence spectrometry. CDs@nanoMIPs demonstrated a notable blue fluorescence when excited at 350 nm, along with excellent photostability and a negative zeta potential. These nanostructured particles (59 nm) exhibited moderate polydispersity and a spherical morphology. The FT-IR spectrum deviated from that of conventional CDs, aligning more closely with the template epitope. When in contact with C. jejuni, CDs@nanoMIPs induced a significant increase in fluorescence intensity, enabling the efficient bacterial detection. This interaction showed exceptional affinity and sensitivity towards C. jejuni, featuring a linear range of 1 × 101–1 × 108 CFU mL−1 (R2 = 0.98) and a low detection limit of 4.6 CFU mL−1. CDs@nanoMIPs-based C. jejuni sensors marked a novel approach to pathogen detection.
Web of Science Eşleşmesi Bulundu
6
WoS Atıf
208
Cilt
Article
Belge Türü
Kaynak: MICROCHEMICAL JOURNAL
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 8.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2025 yılı verileri
Microchemical Journal
Q2
SJR Quartile
0,686
SJR Skoru
126
H-Index
Kategoriler: Analytical Chemistry (Q2) · Spectroscopy (Q2)
Alanlar: Chemistry
Ülke: United States · Elsevier Inc.
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

WoS | Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.

Makale Bilgileri

Dergi Microchemical Journal
ISSN 0026-265X
Yıl 2025 / 1. ay
Cilt / Sayı 208
Sayfalar 112301 – 112301
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
JCR Quartile Q1
Teşvik Puanı 3,00 · YÖKSİS Akademik Teşvik
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 6 kişi
Erişim Türü Elektronik
Sponsor Tübitak 2219
Alan Mühendislik Temel Alanı Biyomühendislik Nanoteknoloji Biyomedikal Tanı ve Terapi Biyoteknoloji

YÖKSİS Yazar Kaydı

Yazar Adı DİNÇ SALİHA,Tjardts Tim,Maschkowitz Gregor,Lukaszczuk Vivian,Gharibzahedi Seyed Mohammad Taghi,ALTINTAŞ ZEYNEP
YÖKSİS ID 8201488

Metrikler

Scopus Atıf 8
Havuz Atıfları 0
JCR Quartile Q1
Teşvik Puanı 3,00
Yazar Sayısı 6