Scopus Eşleşmesi Bulundu
0
Atıf
55
Cilt
226-237
Sayfa
Özet
The aim of this finite element stress analysis (FEA) study was to assess the effect of separated files (SF) that were broken at two levels (at apical 4 and 9 mm) on the biomechanics of premolars and to determine if removal techniques affect stresses. Six lower premolar teeth were screened on computerized microtomography (micro-CT), standard access cavities were prepared, working lengths were determined, and root canals were prepared (Protaper files, Protaper Universal, Dentsply, Switzerland). Notches were created on the final shaping-file F3 at points 4 and 9 mm from the file tips, inserted in the canals, and squeezed at the apical to break. The roots were rescreened, and SFs were removed by using a Masseran kit (MK; Micro Mega, France), ultrasonic tips (UT; Satelec, Acteon group, France), and the bypass (BP) technique. Final scans were obtained and converted into three-dimensional FEA models. The following conditions were then simulated: a) root-filled tooth with SF; b) root-filled tooth after removal of the SF by using MK, UT, or BP techniques. The models were loaded axially (from two directions) and vertically (300 N), and von Mises stresses were then analyzed. SFs increased the stresses within the root. Longer SFs cause higher stresses within the root and thus should be removed, while short SFs could be kept considering the other clinical factors. Removal via MK caused the highest stresses within the roots among the techniques used. Axial loading caused higher stresses at the cervical side, while the stresses moved toward the apical side under vertical loading. SFs increase the stresses within the root. Long SFs should be removed while short SFs can be left (considering other clinical factors that may affect the success of the treatment). Removing short SFs located at the apical side negatively affects the biomechanics of the teeth, and this effect is more dramatic with the MK technique.
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi
Otomatik ISSN Eşleştirmesi
2023 yılı verileri
Strength of Materials
Q4
SJR Quartile
0,213
SJR Skoru
28
H-Index
Kategoriler: Mechanics of Materials (Q4)
Alanlar: Engineering
Ülke: United States
· Springer New York
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir.
Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.
Anahtar Kelimeler
Bu makale için anahtar kelime bilgisi bulunmuyor.
Makale Bilgileri
Dergi
Springer Science and Business Media LLC
ISSN
0039-2316
Yıl
2023
/ 1. ay
Cilt / Sayı
55
/ 1
Sayfalar
226 – 237
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SCI-Expanded
JCR Quartile
Q4
Teşvik Puanı
3,60
· YÖKSİS Akademik Teşvik
Yayın Dili
Türkçe
Kapsam
Uluslararası
Toplam Yazar
2 kişi
Erişim Türü
Basılı+Elektronik
Alan
Sağlık Bilimleri Temel Alanı
Endodonti
YÖKSİS Yazar Kaydı
Yazar Adı
ahadov ehed, BELLİ SEMA
YÖKSİS ID
7781553