Scopus Eşleşmesi Bulundu
12
Atıf
216
Cilt
Özet
In postmastectomy radiation therapy (PMRT), the adequate skin surface dose remains a problem. In this study, the effect of different CTV shrinkage and Skin flash margins on skin dose was investigated, and the accuracy of skin surface dose calculated by TPS for PMRT using thermoluminescent dosimeters (TLDs) was evaluated. Eighty-eight measurement points were determined on the Alderson Rando phantom. To determine the effects of shrinkage margin on skin dose, separate CTVs were generated for 2 mm, 3 mm and 5 mm shrinkage. The prescribed dose was 50 Gy to CTV with a daily fraction dose of 2 Gy. A total of 12 plans were created using four different skin flash thicknesses for each CTV shrinkage margin. After applying 0 mm, 10 mm, 15 mm and 20 mm skin flash thicknesses for each area of the 7F-IMRT treatment plan, the plans were recalculated, and the SF-0, SF-10, SF-15 and SF-20 plans were created, respectively. The increase in skin flash thickness in IMRT plans resulted in a significant increase in skin dose. There was a significant difference between TPS and TLD doses in all chest wall areas for SF-0, SF-10, and SF-15 (p < 0.05). However, there was no significant difference in all areas of the chest wall for SF-20 (p > 0.05). The shrinkage margin thickness of the CTV was found to be inversely proportional to the skin dose for all treatment plans. In tumors near the surface, bolus or skin flash techniques can get the skin adequately dosed. However, the skin flash technique has shown superiority in the application. In PMRT, it is recommended to keep the shrinkage margin as small as possible and use the skin flash thickness of 20 mm for the skin to receive a sufficient dose.
Web of Science Eşleşmesi Bulundu
12
WoS Atıf
216
Cilt
Article
Belge Türü
Kaynak: RADIATION PHYSICS AND CHEMISTRY
Anahtar Kelimeler (WoS)
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 12.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi
Otomatik ISSN Eşleştirmesi
2024 yılı verileri
Radiation Physics and Chemistry
Q2
SJR Quartile
0,543
SJR Skoru
105
H-Index
Kategoriler: Radiation (Q2)
Alanlar: Physics and Astronomy
Ülke: United Kingdom
· Elsevier Ltd
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir.
Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.
Anahtar Kelimeler
YÖKSİS WoS |
Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.
Makale Bilgileri
Dergi
Radiation Physics and Chemistry
ISSN
0969-806X
Yıl
2024
/ 3. ay
Cilt / Sayı
216
Sayfalar
1 – 7
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SCI-Expanded
JCR Quartile
Q1
Teşvik Puanı
14,40
· YÖKSİS Akademik Teşvik
Yayın Dili
İngilizce
Kapsam
Uluslararası
Toplam Yazar
2 kişi
Erişim Türü
Basılı+Elektronik
Alan
Sağlık Bilimleri Temel Alanı
Sağlık Fiziği
Radyoterapi
YÖKSİS Yazar Kaydı
Yazar Adı
GÜL OSMAN VEFA,DÜZOVA MÜRSEL
YÖKSİS ID
7621874