CANLI
Yükleniyor Veriler getiriliyor…
ESCI Özgün Makale Scopus
Clinical Performance and Patient Satisfaction of Hybrid Contact Lenses in Patients with Keratoconus
TURKISH JOURNAL OF OPHTHALMOLOGY 2023 Cilt 53 Sayı 4
Scopus Eşleşmesi Bulundu
2
Atıf
53
Cilt
206-212
Sayfa
🔓
Açık Erişim
Özet
Objectives: The aim of the study was to evaluate the fitting process, clinical performance, and patient satisfaction of hybrid contact lenses (HCL) in patients with keratoconus (KC). Materials and Methods: Sixty-eight KC patients (35 female, 33 male) who were prescribed HCL were included in the study. Corneal topographic parameters, best corrected visual acuity (BCVA) with eyeglasses, the number of HCL trials, prescribed HCL base curve (BC), and visual acuity with HCL were recorded from hospital records. A contact lens satisfaction survey was sent to the patients via email or WhatsApp and the data was statistically analyzed using IBM SPSS Statistics version 22.0. Results: The study included 110 eyes of 68 patients with a mean age of 27.34±8 years (range: 12-48 years). According to the Amsler-Krumeich classification, 35.5% of the eyes were stage 1, 50.9% were stage 2, and 13.5% were stage 3 or 4. Mean K1, K2, and Kmean values were 7.14±0.50 mm (range 5.72-8.30 mm), 6.63±0.49 mm (range 5.07-7.84 mm), and 6.89±0.48 mm (range 5.39-8.06 mm), respectively. The average number of lens trials was 1.59±0.82 (range 1-4). The mean BC of the prescribed HCL was 6.84±0.50 mm (range 5.60-8.00 mm). BCVA with glasses was 0.36±0.2 (range 0.05-0.8), and 0.80±0.14 (range 0.3-1.0) with HCL (p<0.0001). The overall survey score was 3.54 out of 5, the overall satisfaction score was 3.27, the average vision satisfaction score was 3.62, the average satisfaction score for lens insertion and removal was 3.01, and the average satisfaction score for lens comfort was 2.97. Conclusion: Prescribed HCL BC is usually close to the topographic Kmean value and in most of the patients, fitting was successful with the first or second CL trial. The overall satisfaction score was moderate to good and the disadvantages were low comfort compared to soft CL, difficulty with insertion and removal, short lens life, and high cost.
Web of Science Eşleşmesi Bulundu
2
WoS Atıf
53
Cilt
Article
Belge Türü
Kaynak: TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY · s. 206-212
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 2.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.

Anahtar Kelimeler

WoS | Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.

Makale Bilgileri

Dergi TURKISH JOURNAL OF OPHTHALMOLOGY
ISSN 1300-0659
Yıl 2023 / 8. ay
Cilt / Sayı 53 / 4
Sayfalar 206 – 212
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks ESCI
Teşvik Puanı 2,70 · YÖKSİS Akademik Teşvik
Yayın Dili Türkçe
Kapsam Uluslararası
Toplam Yazar 4 kişi
Erişim Türü Basılı+Elektronik
Alan Sağlık Bilimleri Temel Alanı Göz Hastalıkları

YÖKSİS Yazar Kaydı

Yazar Adı Serdarov Aydoğdu, BOZKURT BANU, KARAKÜÇÜK YALÇIN, OKUDAN SÜLEYMAN
YÖKSİS ID 7325321

Metrikler

Scopus Atıf 2
Havuz Atıfları 0
Teşvik Puanı 2,70
Yazar Sayısı 4