Evaluation of incidental testicular dose with thermoluminescence dosimetry during prostate radiotherapy
Medical Dosimetry 2022 Cilt 47 Sayı 3
Scopus Eşleşmesi Bulundu
4
Atıf
47
Cilt
203-206
Sayfa
Özet
The aim of this study was to investigate incidental testicular doses during intensity modulated radiation therapy (IMRT) in patients treated with prostate radiotherapy only (PORT) and whole pelvis radiotherapy (WPRT). A total of 34 prostate cancer patients with intermediate and high risk were included in this prospective study. Each patient in the intermediate risk group received a total of 78 Gy in 39 fractions for prostate and seminal vesicles. In patients in the high risk group, 2 Gy daily fraction dose for pelvic lymphatics was given to 50 Gy, and then 78 Gy was given to prostate and seminal vesicles volumes. Treatment plans were created for all patients using the IMRT technique with 6MV. Testicular doses were measured for WPRT and PORT by thermoluminescence dosimetry (TLD) detectors placed on testis surface. Testicular doses measured for WPRT and PORT were compared. The isocenter to testicular distance for WPRT and PORT was 16.83-cm (13.20 to 18.80-cm) and 11.15 cm (9.10 to 13.00-cm), respectively. The mean testicular dose measurements of TPS and TLD per fraction during PORT were 2.41 cGy (1.95 to 3.60 cGy) and 3.70 cGy (2.80 to 5.10 cGy), respectively (p = 0.00). In WPRT irradiation, mean testicular dose values of TPS and TLD per fraction were measured as 3.85 cGy (2.00 to 5.70 cGy) and 5.85 cGy (4.25 to 7.55 cGy), respectively (p = 0.00). The cumulative mean scattered dose for PORT irradiation of 78 Gy in 39 fractions was 144.30 cGy. The mean cumulative dose received by the testis for the high-risk prostate patient was 228.15 cGy. There was a significant difference in testicular dose between WPRT and PORT irradiation. Testicular doses decreased significantly with increasing isocenter-testis distance. Incidental testicular dose during prostate radiotherapy can be significantly detrimental to spermatogenesis. Therefore, the testicles should be contoured as an organ at risk for the estimation of absorbed doses. The use of in vivo dosimetry is recommended for accurate measurement of testicular dose in radiotherapy of prostate cancer for men desiring continued fertility.
Web of Science Eşleşmesi Bulundu
5
WoS Atıf
47
Cilt
Article
Belge Türü
Kaynak: MEDICAL DOSIMETRY · s. 203-206
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 4.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2022 yılı verileri
Medical Dosimetry
Q2
SJR Quartile
0,450
SJR Skoru
48
H-Index
Kategoriler: Radiological and Ultrasound Technology (Q2) · Oncology (Q3) · Radiology, Nuclear Medicine and Imaging (Q3)
Alanlar: Health Professions · Medicine
Ülke: United States · Elsevier Inc.
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

WoS | Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.

Makale Bilgileri

Dergi Medical Dosimetry
ISSN 0958-3947
Yıl 2022 / 8. ay
Cilt / Sayı 47 / 3
Sayfalar 203 – 206
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
JCR Quartile Q4
Teşvik Puanı 2,70 · YÖKSİS Akademik Teşvik
Yayın Dili Türkçe
Kapsam Uluslararası
Toplam Yazar 3 kişi
Erişim Türü Elektronik
Alan Sağlık Bilimleri Temel Alanı Sağlık Fiziği

YÖKSİS Yazar Kaydı

Yazar Adı GÜL OSMAN VEFA,BAŞARAN HAMİT,İNAN GÖKÇEN
YÖKSİS ID 6368294

Metrikler

Scopus Atıf 4
Havuz Atıfları 0
JCR Quartile Q4
Teşvik Puanı 2,70
Yazar Sayısı 3