Scopus Eşleşmesi Bulundu
88
Atıf
39
Cilt
527-542
Sayfa
Özet
Strengthening of shear deficient T-beams is not as easy as rectangular beams due to the presence of slabs. In this study, externally bonded reinforcement (EBR) such type of reinforced concrete shear deficient T-beams with and without anchorage in different CFRP configurations was experimentally and analytically investigated. Pursuant to this goal, nine half-scale T-beams were produced and tested with monotonic loading under four points. Seven of these T-beams are strengthened with partial CFRP strip and one is strengthened with full CFRP wrapped in the shear span. The failures of strengthened beams are initiated with the debonding failure of FRP sheets followed by brittle shear failure. In order to prevent this failure, two specimens with partial CFRP strip are fixed to the beam by using anchors at different angles of 45° and 90°. The experimental results indicated that the contribution of EBR to the shear capacity is significant and depends on different variables such as anchorage angle, strengthening type. Moreover, the strengthening method that gives the most effective results in strengthening T-beams are full wrapping CFRP and partial CFRP with a 45-degree anchorage type. The anchorage application increased the shear capacity by 42.6%∼53.8% compared to the reference specimens. In addition, the anchors with angle of 45° increased stiffness by 37%. In terms of ductility, the best result was given by the type of strengthening where the slabs were broken and the beam was completely wrapped. This method contributed 42%∼80% more to ductility than other methods. The obtained experimental results were also compared with the empirical correlations given by ACI 440.2R-17, TBEC-2019 and FIB-2010 and recommendations are given. Especially in fully wrapped beams, the estimation of ACI was determined to be 96%. The estimations of the other codes are far from meeting the experimental results; therefore, essential improvements should be applied to the codes, especially with regard to CFRP deformation and approaches for anchored connections.
Web of Science Eşleşmesi Bulundu
80
WoS Atıf
39
Cilt
Article
Belge Türü
Kaynak: STRUCTURES
· s. 527-542
Anahtar Kelimeler (WoS)
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 88.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi
Otomatik ISSN Eşleştirmesi
2022 yılı verileri
Structures
Q1
SJR Quartile
0,887
SJR Skoru
70
H-Index
Kategoriler: Architecture (Q1) · Building and Construction (Q1) · Civil and Structural Engineering (Q1) · Safety, Risk, Reliability and Quality (Q1)
Alanlar: Engineering
Ülke: United Kingdom
· Elsevier Ltd
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir.
Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.
Anahtar Kelimeler
CFRP
Reinforced Concrete T-beams
Strengthening
Analytical analysis
Anchorage
Building Codes
Damage analysis
WoS |
Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.
Makale Bilgileri
Dergi
Structures
ISSN
2352-0124
Yıl
2022
/ 5. ay
Cilt / Sayı
39
Sayfalar
1527 – 542
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SCI-Expanded
JCR Quartile
Q2
Teşvik Puanı
2,40
· YÖKSİS Akademik Teşvik
Yayın Dili
İngilizce
Kapsam
Uluslararası
Toplam Yazar
6 kişi
Erişim Türü
Basılı+Elektronik
Alan
Mühendislik Temel Alanı
Makine Mühendisliği
Malzeme Tasarım ve Davranışları
Kompozit Malzemeler
Nanoteknoloji
YÖKSİS Yazar Kaydı
Yazar Adı
ARSLAN MUSA HAKAN, YAZMAN ŞAKİR, Abed Hamad Ahmed, AKSOYLU CEYHUN, ÖZKILIÇ YASİN ONURALP, GEMİ LOKMAN
YÖKSİS ID
6227454