Novel Application Software for the Semi-Automated Analysis of Infrared Meibography Images
Cornea 2019 Cilt 38 Sayı 11
Scopus Eşleşmesi Bulundu
13
Atıf
38
Cilt
1456-1464
Sayfa
Özet
Purpose:To develop semi-automated application software that quickly analyzes infrared meibography images taken with the CSO Sirius Topographer (CSO, Italy) and to compare them to the manual analysis system on the device (Phoenix software platform).Methods:A total of 52 meibography images verified as high quality were used and analyzed through manual and semi-automated meibomian gland (MG) detector software in this study. For the manual method, an experienced researcher circumscribed the MGs by putting dots around grape-like clusters in a predetermined rectangular area, and Phoenix software measured the MG loss area by percentage, which took around 10 to 15 minutes. MG loss was graded from 1 (<25%) to 4 (severe >75%). For the semi-automated method, 2 blind physicians (I and II) determined the area to be masked by putting 5 to 6 dots on the raw images and measured the MG loss area using the newly developed semi-automated MG detector application software in less than 1 minute. Semi-automated measurements were repeated 3 times on different days, and the results were evaluated using paired-sample t test, Bland-Altman, and kappa analysis.Results:The mean MG loss area was 37.24% with the manual analysis and 40.09%, 37.89%, and 40.08% in the first, second, and third runs with the semi-automated analysis (P < 0.05). Manual analysis scores showed a remarkable correlation with the semi-automated analysis performed by 2 operators (r = 0.950 and r = 0.959, respectively) (P < 0.001). According to Bland-Altman analysis, the 95% limits of agreement between manual analysis and semi-automated analysis by operator I were between-10.69% and 5% [concordance correlation coefficient (CCC) = 0.912] and between-9.97% and 4.3% (CCC = 0.923) for operator II. The limit of interoperator agreement in semi-automated analysis was between-4.89% and 4.92% (CCC = 0.973). There was good to very good agreement in grading between manual and semi-automated analysis results (0.76-0.84) and very good interoperator agreement with semi-automated software (0.91) (P < 0.001).Conclusions:For the manual analysis of meibography images, around one hundred dots have to be put around grape-like clusters to determine the MGs, which makes the process too long and prone to errors. The newly developed semi-automated software is a highly reproducible, practical, and faster method to analyze infrared meibography images with excellent correlation with the manual analysis.
Web of Science Eşleşmesi Bulundu
12
WoS Atıf
38
Cilt
Article
Belge Türü
Kaynak: CORNEA · s. 1456-1464
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 13.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2019 yılı verileri
Cornea
Q1
SJR Quartile
1,260
SJR Skoru
141
H-Index
Kategoriler: Ophthalmology (Q1)
Alanlar: Medicine
Ülke: United States · Lippincott Williams and Wilkins
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

WoS | Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.

Makale Bilgileri

Dergi Cornea
ISSN 0277-3740
Yıl 2019 / 1. ay
Cilt / Sayı 38 / 11
Sayfalar 1456 – 1464
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SSCI
Teşvik Puanı 6,48 · YÖKSİS Akademik Teşvik
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 4 kişi
Erişim Türü Elektronik
Alan Sağlık Bilimleri Temel Alanı- Göz Hastalıkları

YÖKSİS Yazar Kaydı

Yazar Adı BOZKURT BANU,DAĞ TAMER,GORCUYEVA SONA,SHEHZAD DANISH
YÖKSİS ID 4348986

Metrikler

Scopus Atıf 13
Havuz Atıfları 0
Teşvik Puanı 6,48
Yazar Sayısı 4