CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded JCR Q1 Özgün Makale Scopus
A new technique for the diagnosis of acute appendicitis: abdominal CT with compression to the right lower quadrant
EUROPEAN RADIOLOGY 2017 Cilt 27 Sayı 8
Scopus Eşleşmesi Bulundu
6
Atıf
27
Cilt
3317-3325
Sayfa
Özet
Objective: To determine the diagnostic accuracy of abdominal CT with compression to the right lower quadrant (RLQ) in adults with acute appendicitis. Methods: 168 patients (age range, 18–78 years) were included who underwent contrast-enhanced CT for suspected appendicitis performed either using compression to the RLQ (n = 71) or a standard protocol (n = 97). Outer diameter of the appendix, appendiceal wall thickening, luminal content and associated findings were evaluated in each patient. Kruskal-Wallis, Fisher’s and Pearson's chi-squared tests were used for statistical analysis. Results: There was no significant difference in the mean outer diameter (MOD) between compression CT scans (10.6 ± 1.9 mm) and standard protocol (11.2 ± 2.3 mm) in patients with acute appendicitis (P = 1). MOD was significantly lower in the compression group (5.2 ± 0.8 mm) compared to the standard protocol (6.5 ± 1.1 mm) (P < 0.01) in patients without appendicitis. A cut-off value of 6.75 mm for the outer diameter of the appendix was found to be 100% sensitive in the diagnosis of acute appendicitis for both groups. The specificity was higher for compression CT technique (67.7 vs. 94.9%). Conclusion: Normal appendix diameter was significantly smaller in the compression-CT group compared to standard-CT group, increasing diagnostic accuracy of abdominal compression CT. Key points: • Normal appendix diameter is significantly smaller in compression CT. • Compression could force contrast material to flow through the appendiceal lumen. • Compression CT may be a CT counterpart of graded compression US.
Web of Science Eşleşmesi Bulundu
4
WoS Atıf
27
Cilt
Article
Belge Türü
Kaynak: EUROPEAN RADIOLOGY · s. 3317-3325
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 6.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2017 yılı verileri
European Radiology
Q1
SJR Quartile
1,943
SJR Skoru
182
H-Index
🔓
Açık Erişim
Kategoriler: Medicine (miscellaneous) (Q1) · Radiology, Nuclear Medicine and Imaging (Q1)
Alanlar: Medicine
Ülke: Germany · Springer Verlag
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

YÖKSİS | Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.

Makale Bilgileri

Dergi EUROPEAN RADIOLOGY
ISSN 0938-7994
Yıl 2017 / 1. ay
Cilt / Sayı 27 / 8
Sayfalar 3317 – 3325
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
JCR Quartile Q1
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 8 kişi
Erişim Türü Basılı
Alan Sağlık Bilimleri Temel Alanı- Radyoloji

YÖKSİS Yazar Kaydı

Yazar Adı KILINÇER ABİDİN, AKPINAR ERHAN, ERBİL BÜLENT, ÜNAL EMRE, KARAOSMANOĞLU ALİ DEVRİM, KAYNAROĞLU ZAFER VOLKAN, AKATA DENİZ, ÖZMEN MUSTAFA NASUH
YÖKSİS ID 3322080

Metrikler

Scopus Atıf 6
Havuz Atıfları 0
JCR Quartile Q1
Yazar Sayısı 8