Comparison Between Prospectively Electrocardiogram-Gated High-Pitch Mode and Retrospectively Electrocardiogram-Gated Mode for Dual-Source CT Coronary Angiography
Polish Journal of Radiology 2015 Cilt 80
Scopus Eşleşmesi Bulundu
6
Atıf
80
Cilt
561-568
Sayfa
Özet
Background: We aimed to report the image quality, relationship between heart rate and image quality, amount of contrast agent given to the patients and radiation doses in coronary CT angiography (CTA) obtained by using high-pitch prospectively ECG-gated “Flash Spiral” technique (method A) or retrospectively ECG-gated technique (method B) using 128×2-slice dual-source CT. Material/Methods: A total of 110 patients who were evaluated with method A and method B technique with a 128×2-detector dual-source CT device were included in the study. Patients were divided into three groups based on their heart rates during the procedure, and a relationship between heart rate and image quality were evaluated. The relationship between heart rate, gender and radiation dose received by the patients was compared. Results: A total of 1760 segments were evaluated in terms of image quality. Comparison of the relationship between heart rate and image quality revealed a significant difference between heart rate <60 beats/min group and >75 beats/min group whereas <60 beats/min and 60-75 beats/min groups did not differ significantly. The average effective dose for coronary CTA was calculated as 1.11 mSv (0.47–2.01 mSv) for method A and 8.22 mSv (2.19–12.88 mSv) for method B. Conclusions: Method A provided high quality images with doses as low as <1 mSv in selected patients who have low heart rates with a high negative predictive value to rule out coronary artery disease. Although method B increases the amount of effective dose, it provides high diagnostic quality images for patients who have a high heart rate and arrhythmia which makes it is difficult to obtain images.
Web of Science Eşleşmesi Bulundu
4
WoS Atıf
80
Cilt
Article
Belge Türü
Kaynak: POLISH JOURNAL OF RADIOLOGY · s. 561-568
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 6.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.

Anahtar Kelimeler

WoS | Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.

Makale Bilgileri

Dergi Polish Journal of Radiology
ISSN 0137-7183
Yıl 2015 / 1. ay
Cilt / Sayı 80
Sayfalar 561 – 568
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 6 kişi
Erişim Türü Elektronik
Alan Sağlık Bilimleri Temel Alanı- Radyoloji

YÖKSİS Yazar Kaydı

Yazar Adı KOPLAY MUSTAFA,ÇELİK MAHMUT,AVCI AHMET,ERDOĞAN HASAN,DEMİR KENAN,SİVRİ MESUT
YÖKSİS ID 3026476

Metrikler

Scopus Atıf 6
Havuz Atıfları 0
Yazar Sayısı 6