CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded Özgün Makale Scopus
Reinforcement effect of polyethylene fibre in root-filled teeth: comparison of two restoration techniques
International Endodontic Journal 2006 Cilt 39 Sayı 2
Scopus Eşleşmesi Bulundu
108
Atıf
39
Cilt
136-142
Sayfa
Özet
Aim: To compare in vitro two different fibre placement techniques on reinforcement of root-filled molar teeth with mesio-occluso-distal (MOD) cavities. Methodology: Fifty sound extracted human mandibular molars were used (n = 10). Group 1 served as control. From group 2-5, endodontic access and standard MOD cavities were prepared. Following root canal treatment, group 2 was kept unrestored. In groups 3 and 4, the teeth were restored with composite resin (AP-X; Kuraray, Japan). A groove was prepared on occlusal surface of the finished restorations in group 4 from buccal to lingual direction. Polyethylene woven fibre (Ribbond; Seattle, WA, USA) was inserted in the groove in combination with flowable resin that was cured for 20 s and covered with composite resin. Cavity surfaces were covered with flowable resin in group 5, and polyethylene fibre was placed into the bed of resin in a buccal to lingual direction before the composite restoration was placed. All specimens were stored in 100% humidity at 37°C for 24 h. Compressive loading of the teeth was performed by a universal testing machine at a crosshead speed of 0.5 mm min -1 until failure. The data were recorded in Newton and submitted to anova and Tukey post hoc test. Results: The mean load necessary to fracture the samples in each group was: G1: 1671.57 ± 131.54a; G2: 375.21 ± 34.30b; G3: 749.47 ± 124.54c; G4: 1224.36 ± 132.17d; G5: 926.88 ± 118.28e. Different superscript letters demonstrate significant difference between groups. Conclusions: Polyethylene fibre use over or under MOD composite restorations significantly increased fracture strength. However, when the fibre was placed on the occlusal surface of the restoration in buccal to lingual direction, significantly higher fracture resistance was observed. © 2006 International Endodontic Journal.
Web of Science Eşleşmesi Bulundu
90
WoS Atıf
39
Cilt
Article
Belge Türü
Kaynak: INTERNATIONAL ENDODONTIC JOURNAL · s. 136-142
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 108.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.

Anahtar Kelimeler

WoS | Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.

Makale Bilgileri

Dergi International Endodontic Journal
ISSN 0143-2885
Yıl 2006 / 2. ay
Cilt / Sayı 39 / 2
Sayfalar 136 – 142
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 3 kişi
Erişim Türü Elektronik
Alan Sağlık Bilimleri Temel Alanı- Endodonti

YÖKSİS Yazar Kaydı

Yazar Adı BELLİ SEMA,yildirim cihan,ERDEMİR ALİ
YÖKSİS ID 2877024

Metrikler

Scopus Atıf 108
Havuz Atıfları 0
Yazar Sayısı 3