Scopus Eşleşmesi Bulundu
13
Atıf
29
Cilt
577-582
Sayfa
🔓
Açık Erişim
Özet
Background: The purpose of this study is to compare field-in-field radiotherapy (FIF) with conformal radiotherapy (CRT) in terms of dosimetric benefits for early stage endometrial cancer patients. Materials and methods: Ten consecutive early stage endometrial cancer patients who underwent adjuvant external beam radiotherapy were included in the study. For each patient, two different treatment plans were created. FIF and CRT plans were compared for doses in the planning target volume (PTV), the organ at risk (OAR) volumes including rectum, bladder, bowel, bilateral femurs and bone marrow, the dose homogeneity index, and the monitor unit counts required for the treatment. Results: The FIF technique significantly reduced the maximum dose of the PTV, rectum, bladder, bowel, left femur, right femur and bone marrow (p values were: <0.001, 0.031, 0.003, <0.001, 0.001, 0.001 and <0.001 respectively). When the OAR volumes irradiated with >30 and >45Gy were compared, the results were in favor of the FIF technique. The volumes of rectum, bladder, bowel, left femur, right femur and bone marrow receiving more than the prescription dose of 45Gy were significantly reduced with FIF technique (p values were 0.016, 0.039, 0.01, 0.04, 0.037 and 0.01 respectively). The dose homogeneity index (DHI) was significantly improved with FIF technique (p<0.001). Conclusions: FIF allowed more homogeneous dose distribution in the PTV and reduced the doses received by OAR. Considering the lower maximum doses in the OAR and PTV, FIF technique seems to be more advantageous than CRT during adjuvant radiotherapy for early stage endometrial cancer patients. © 2012 Associazione Italiana di Fisica Medica.
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 13.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi
Otomatik ISSN Eşleştirmesi
2013 yılı verileri
Physica Medica
Q2
SJR Quartile
0,703
SJR Skoru
71
H-Index
Kategoriler: Biophysics (Q2) · Medicine (miscellaneous) (Q2) · Physics and Astronomy (miscellaneous) (Q2) · Radiology, Nuclear Medicine and Imaging (Q2)
Alanlar: Biochemistry, Genetics and Molecular Biology · Medicine · Physics and Astronomy
Ülke: Italy
· Associazione Italiana di Fisica Medica
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir.
Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.
Anahtar Kelimeler
Bu makale için anahtar kelime bilgisi bulunmuyor.
Makale Bilgileri
Dergi
Physica Medica
ISSN
11201797
Yıl
2013
/ 11. ay
Cilt / Sayı
29
/ 6
Sayfalar
577 – 582
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SCI-Expanded
Yayın Dili
İngilizce
Kapsam
Uluslararası
Toplam Yazar
8 kişi
Erişim Türü
Elektronik
Alan
Sağlık Bilimleri Temel Alanı-
Tıbbi Onkoloji
YÖKSİS Yazar Kaydı
Yazar Adı
YAVAŞ GÜLER,YAVAŞ ÇAĞDAŞ,Büyükyörük Ahmet,ACAR DEMİR HİLAL,Çobanoğlu Gökçen,SEÇİLMİŞ KERİMOĞLU ÖZLEM,ATA ÖZLEM,ÇELİK ÇETİN
YÖKSİS ID
2308463