10 cm H2O PEEP application in laparoscopic surgery and cerebral oxygenation: a comparative study with INVOS and FORESIGHT
Surgical Endoscopy 2016 Cilt 30 Sayı 3
Scopus Eşleşmesi Bulundu
7
Atıf
30
Cilt
971-978
Sayfa
Özet
Introduction: In the present study, changes in hemodynamic parameters and cerebral oxygen saturation (rSO2) associated with 10 cm H2O PEEP application were investigated, which is assumed beneficial for the respiratory functions and oxygenation during laparoscopic cholecystectomy (LC) applied at 30° head-up left side position. Data gathered via two devices, namely INVOS and FORESIGHT, were compared. Methods: After both the ethics committee approval from the hospital and patients’ written consents were obtained, patients undergoing elective laparoscopic surgery (only ASA I–II) were randomly divided into two groups (Clinical trials protocol NCT02071550). Sensors of INVOS and FORESIGHT devices were placed on the right side at the forehead region. In total, 11 evaluation periods were formed, namely pre-induction (1st period), post-induction (2nd period), abdominal insufflation outset (3rd period), post-insufflation at 5-min intervals (4th, 5th, 6th, 7th, and 8th period), at the end of insufflation (9th period), at the end of operation (10th period), and at the end of anesthesia (11th period). While one of the groups did not receive PEEP (ZEEP group), the other group received 10 cm H2O along with abdominal insufflation (PEEP group). Demographic data, hemodynamic values, and rSO2 values were recorded for both groups at all 11 periods. Results: A total of 44 patients in two groups, each group containing 22 individuals, were included in the study. Systolic, diastolic, and mean arterial pressures, etCO2 and SO2 values, and demographic data were found to be similar in both groups. Heart rate was observed to be higher in the PEEP group starting with the PEEP administration. INVOS rSO2 values were found similar in both groups. However, FORESIGHT rSO2 values were found to be higher in the PEEP group compared to the ZEEP group. No patient had cerebral desaturation in both groups throughout the study. Discussion: Application of PEEP with 10 cm H2O during abdominal insufflation could increase the rSO2 value and heart rate in patients undergoing laparoscopic cholecystectomy. However, all changes observed were within normal limits. FORESIGHT device yielded more compatible results with hemodynamic data compared to INVOS.
Web of Science Eşleşmesi Bulundu
5
WoS Atıf
30
Cilt
Article
Belge Türü
Kaynak: SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES · s. 971-978
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 7.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2016 yılı verileri
Surgical Endoscopy
Q1
SJR Quartile
1,720
SJR Skoru
178
H-Index
Kategoriler: Surgery (Q1)
Alanlar: Medicine
Ülke: United States · Springer
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

Makale Bilgileri

Dergi Surgical Endoscopy
ISSN 0930-2794
Yıl 2016 / 3. ay
Cilt / Sayı 30 / 3
Sayfalar 971 – 978
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
JCR Quartile Q1
Teşvik Puanı 9,00 · YÖKSİS Akademik Teşvik
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 8 kişi
Erişim Türü Basılı+Elektronik
Alan Sağlık Bilimleri Temel Alanı- Kalp ve Damar Cerrahisi

YÖKSİS Yazar Kaydı

Yazar Adı Uçar Kemerci Perihan,Demir Aslı,Aydınlı Bahar,YILDIRIM GÜÇLÜ ÇİĞDEM,KARADENİZ ÜMİT,ÇİÇEK ÖMER FARUK,Taşoğlu İrfan,ÖZGÖK AYŞEGÜL
YÖKSİS ID 2300069

Metrikler

Scopus Atıf 7
Havuz Atıfları 0
JCR Quartile Q1
Teşvik Puanı 9,00
Yazar Sayısı 8