Scopus Eşleşmesi Bulundu
64
Atıf
83
Cilt
1914-1919
Sayfa
Özet
Purpose Arterial spin labeling perfusion imaging (ASL-PI) is a non-invasive perfusion imaging method that can be used for evaluation and quantification of cerebral blood flow (CBF). Aim of our study was to evaluating the efficiency of ASL in histopathological grade estimation of glial tumors and comparing findings with dynamic susceptibility contrast perfusion imaging (DSC-PI) method. Methods This study involved 33 patients (20 high-grade and 13 low-grade gliomas). Multiphase multislice pulsed ASL MRI sequence and a first-passage gadopentetate dimeglumine T2*-weighted gradient-echo single-shot echo-planar sequence were acquired for all the patients. For each patient, perfusion relative signal intensity (rSI), CBF and relative CBF (rCBF) on ASL-PI and relative cerebral blood volume (rCBV) and relative cerebral blood flow (rCBF) values on DSC-PI were determined. The relative signal intensity of each tumor was determined as the maximal SI within the tumor divided by SI within symetric region in the contralateral hemisphere on ASL-PI. rCBV and rCBF were calculated by deconvolution of an arterial input function. Relative values of the lesions were obtained by dividing the values to the normal appearing symmetric region on the contralateral hemisphere. For statistical analysis, Mann-Whitney ranksum test was carried out. Receiver operating characteristic curve (ROC) analysis was performed to assess the relationship between the rCBF-ASL, rSI-ASL, rCBV and rCBF ratios and grade of gliomas. Their cut-off values permitting best discrimination was calculated. The correlation between rCBV, rCBF, rSI-ASL and rCBF-ASL and glioma grade was assessed using Spearman correlation analysis. Results There was a statistically significant difference between low and high-grade tumors for all parameters. Correlation analyses revealed significant positive correlations between rCBV and rCBF-ASL (r = 0.81, p < 0.001). However correlation between rCBF and rCBF-ASL was weaker (r = 0.64, p < 0.001). Conclusion Arterial spin labeling is an employable imaging technique for evaluating tumor perfusion non-invasively and may be useful in differentiating high and low grade gliomas. © 2014 Elsevier Ireland Ltd.
Web of Science Eşleşmesi Bulundu
58
WoS Atıf
83
Cilt
Article
Belge Türü
Kaynak: EUROPEAN JOURNAL OF RADIOLOGY
· s. 1914-1919
Anahtar Kelimeler (WoS)
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 64.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi
Otomatik ISSN Eşleştirmesi
2014 yılı verileri
European Journal of Radiology
Q1
SJR Quartile
1,181
SJR Skoru
139
H-Index
Kategoriler: Medicine (miscellaneous) (Q1) · Radiology, Nuclear Medicine and Imaging (Q1)
Alanlar: Medicine
Ülke: Ireland
· Elsevier Ireland Ltd
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir.
Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.
Anahtar Kelimeler
WoS |
Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.
Makale Bilgileri
Dergi
European Journal of Radiology
ISSN
0720048X
Yıl
2014
/ 10. ay
Cilt / Sayı
83
/ 10
Sayfalar
1914 – 1919
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SCI-Expanded
Yayın Dili
İngilizce
Kapsam
Uluslararası
Toplam Yazar
8 kişi
Erişim Türü
Elektronik
Alan
Sağlık Bilimleri Temel Alanı-
Radyoloji
YÖKSİS Yazar Kaydı
Yazar Adı
CEBECİ HAKAN,AYDIN ÖMER,ÖZTÜRK IŞIK ESİN,GÜMÜŞ ÇAĞIL,İNECİKLİ MEHMET FATİH,BEKAR AHMET,KOCAELİ HASAN,HAKYEMEZ BAHATTİN
YÖKSİS ID
2290184