CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded Özgün Makale Scopus
Safety and efficacy outcomes in patients undergoing pulmonary vein isolation with second generation cryoballoon
Europace 2015 Cilt 17 Sayı 3
Scopus Eşleşmesi Bulundu
95
Atıf
17
Cilt
379-387
Sayfa
🔓
Açık Erişim
Özet
Aims The second-generation cryoballoon (Arctic Front Advance™) (Arc-Adv-CB) has a redesigned injection system which distributes the refrigerant homogenously to the frontal balloon surface. The aim of this study was to compare the efficacy and safety of the Arc-Adv-CB and its predecessor (Arctic Front™) (Arc-CB) in patients who underwent pulmonary vein isolation (PVI) for atrial fibrillation (AF). Methods and results Three hundred and six patients (55.35 ± 10.60 years, 47.05% male) were included in the study. A total of 1205 pulmonary veins were attempted for PVI with either Arc-CB or Arc-Adv-CB. The follow-up durations were 30 (23-38) and 10 (8-13) months in Arc-CB and Arc-Adv-CB groups, respectively (P < 0.001). When the blanking period was considered, freedom from AF after a single ablation procedure was 68.53 and 90.83% in patients undergoing PVI with Arc-CB and Arc-Adv-CB, respectively. The most frequent complication was transient phrenic nerve palsy (PNP) which occurred in five(2.54%) and nine(8.26%) of patients undergoing PVI with Arc-CB and Arc-Adv-CB, respectively (P = 0.040). Left atrial (LA) diameter (hazard ratio, HR: 3.552, 95% CI: 2.034-6.201, P < 0.001), smoking history (HR:1.643, 95% CI: 1.011-2.671, P = 0.045), persistent AF (HR:1.725, 95% CI: 1.021-2.915, P = 0.041), duration of AF (HR:1.039, 95% CI: 1.000-1.080, P = 0.047), and early AF recurrence (HR:2.399, 95% CI: 1.443-3.989, P < 0.001) were associated with increased late AF recurrence. On the other hand, intraprocedural vagal reactions (HR: 0.550, 95% CI: 0.331-0.915, P = 0.021) and Arc-Adv-CB use (HR: 0.441, 95% CI: 0.225-0.866, P = 0.017) were associated with lower late AF recurrence. Left atrial diameter (HR: 3.072, 95% CI: 1.646-5.732, P < 0.001), early AF recurrence (HR: 1.906, 95% CI: 1.103-3.291, P = 0.021), and Arc-Adv-CB use (HR: 0.472, 95% CI: 0.239-0.931, P = 0.030) were independent predictors for late AF recurrence. Conclusion Our study has shown that Arc-Adv-CB use is associated with lower late AF recurrences at the cost of an increased risk for PNP.
Web of Science Eşleşmesi Bulundu
82
WoS Atıf
17
Cilt
Article
Belge Türü
Kaynak: EUROPACE · s. 379-387
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 95.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2015 yılı verileri
Europace
Q1
SJR Quartile
2,412
SJR Skoru
137
H-Index
Kategoriler: Cardiology and Cardiovascular Medicine (Q1) · Physiology (medical) (Q1)
Alanlar: Medicine
Ülke: United Kingdom · Oxford University Press
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

WoS | Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.

Makale Bilgileri

Dergi Europace
ISSN 1099-5129
Yıl 2015 / 2. ay
Cilt / Sayı 17 / 3
Sayfalar 379 – 387
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 11 kişi
Erişim Türü Elektronik
Alan Sağlık Bilimleri Temel Alanı- Kardiyoloji

YÖKSİS Yazar Kaydı

Yazar Adı AYTEMİR KUDRET,Gurses K M,YALÇIN MUHAMMED ULVİ,KOÇYİĞİT DUYGU,DURAL MUHAMMET,EVRANOS BANU,YORGUN HİKMET,Ates A H,ŞAHİNER MEHMET LEVENT,KAYA ERGÜN BARIŞ,Oto M A
YÖKSİS ID 2258688

Metrikler

Scopus Atıf 95
Havuz Atıfları 0
Yazar Sayısı 11