CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded Özgün Makale Scopus
Safety and efficacy outcomes of protamine administration for heparin reversal following cryoballoon based pulmonary vein isolation
Journal of Interventional Cardiac Electrophysiology 2015 Cilt 43 Sayı 2
Scopus Eşleşmesi Bulundu
20
Atıf
43
Cilt
161-167
Sayfa
Özet
Purpose: Anticoagulation with heparin is required during catheter ablation of atrial fibrillation (AF) to reduce systemic thromboembolism. In this study, we aim to compare safety and efficacy outcomes between patients who receive protamine administration for reversal of heparin and those who do not, following cryoballoon-based pulmonary vein isolation (PVI) for AF. Methods: Patients with symptomatic paroxysmal or persistent AF despite ≥1 antiarrhythmic drug(s) were scheduled for PVI per the recent consensus recommendations. Some patients were administered protamine at the end of the procedure depending on the operator’s choice. Results: Among 380 patients [48.2 % male, 56 (20–86) years] that were enrolled, 188 patients received protamine at the end of the procedure. Baseline characteristics did not differ between groups (p > 0.05). Mean protamine dose was 39.1 ± 6.4 mg. Only 1 patient developed rash following protamine infusion. Hospital stay was significantly shorter in patients who were administered protamine (1 [1–5] vs. 2 [1–7] days, p < 0.001). Hematoma/pseudoaneurysm or femoral AV fistula requiring surgical or interventional repair in the femoral access site occurred in 2 (1.1 %) patients who received protamine and 12 (6.3 %) patients who did not (p = 0.011). Deep vein thrombosis was seen in 1 patient in whom protamine was not administered (p = 0.499). Conclusion: To the best of our knowledge, this is one of the largest series showing that protamine administration for heparin reversal in patients undergoing cryoballoon-based PVI allows quicker sheath removal and minimizes the risk of potential vascular complications without causing an increase in thrombotic events.
Web of Science Eşleşmesi Bulundu
17
WoS Atıf
43
Cilt
Article
Belge Türü
Kaynak: JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY · s. 161-167
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 20.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2015 yılı verileri
Journal of Interventional Cardiac Electrophysiology
Q1
SJR Quartile
0,964
SJR Skoru
66
H-Index
Kategoriler: Medicine (miscellaneous) (Q1) · Cardiology and Cardiovascular Medicine (Q2) · Physiology (medical) (Q2)
Alanlar: Medicine
Ülke: United States · Springer
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

WoS | Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.

Makale Bilgileri

Dergi Journal of Interventional Cardiac Electrophysiology
ISSN 1383-875X
Yıl 2015 / 8. ay
Cilt / Sayı 43 / 2
Sayfalar 161 – 167
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 10 kişi
Erişim Türü Elektronik
Alan Sağlık Bilimleri Temel Alanı- Romatoloji

YÖKSİS Yazar Kaydı

Yazar Adı Gurses Kadri Murat,KOÇYİĞİT DUYGU,YALÇIN MUHAMMED ULVİ,EVRANOS BANU,YORGUN HİKMET,ŞAHİNER MEHMET LEVENT,KAYA ERGÜN BARIŞ,Oto Mehmet Ali,ÖZER NECLA,AYTEMİR KUDRET
YÖKSİS ID 2258622

Metrikler

Scopus Atıf 20
Havuz Atıfları 0
Yazar Sayısı 10