Özet
Purpose: Several studies have demonstrated that left ventricular diastolic dysfunction (LVDD) and left atrial pressure (LAP), as a surrogate marker of LVDD, were associated with atrial fibrillation (AF) recurrence following radiofrequency catheter ablation (RFCA) for AF. In this study, we aimed to investigate the individual impact of several left ventricular diastolic function parameters on outcomes of cryoablation for paroxysmal AF using second-generation cryoballoon. Methods: One hundred seventy patients who were scheduled for cryoablation with second-generation cryoballoon were included in this prospective study. All patients underwent comprehensive transthoracic and transesophageal echocardiographic examinations during sinus rhythm a day before catheter ablation. LAP was measured via transseptal sheath at the beginning of the ablation procedure. Results: One hundred seventy patients (57.09 ± 11.80 years, 47.06 % male) were involved in the study. At a median follow-up of 19 months, when blanking period of 3 months was considered, freedom from AF after a single ablation procedure was 84.71 %. Patients with AF recurrence had significantly greater left atrial volume index (LAVI) (p = 0.005) and LAP (p < 0.001). Patients with AF recurrence had lower septal eʹ wave (p = 0.013), and higher E/eʹ ratio (p = 0.014). LAVI (p = 0.007) and LAP (p = 0.006) were independent predictors of AF recurrence. A cut-off value of 13.50 mmHg for LAP measured during the procedure was associated with a sensitivity and specificity of 80.8 and 84.7 % (p = 0.005) for predicting AF recurrence. Conclusions: Pre-procedural LAVI and procedural LAP measurement have clinical importance in predicting AF recurrence in patients undergoing cryoablation with second-generation cryoballoon. Effectiveness of cryoablation is reduced in patients with greater LAVI and LAP.
Web of Science Eşleşmesi Bulundu
22
WoS Atıf
46
Cilt
Article
Belge Türü
Kaynak: JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY · s. 145-151
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 24.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2016 yılı verileri
Journal of Interventional Cardiac Electrophysiology
Q1
SJR Quartile
0,975
SJR Skoru
66
H-Index
Kategoriler: Medicine (miscellaneous) (Q1) · Cardiology and Cardiovascular Medicine (Q2) · Physiology (medical) (Q2)
Alanlar: Medicine
Ülke: United States · Springer
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

WoS | Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.

Makale Bilgileri

Dergi Journal of Interventional Cardiac Electrophysiology
ISSN 1383-875X
Yıl 2016 / 8. ay
Cilt / Sayı 46 / 2
Sayfalar 145 – 151
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
Teşvik Puanı 12,60 · YÖKSİS Akademik Teşvik
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 8 kişi
Erişim Türü Elektronik
Alan Sağlık Bilimleri Temel Alanı- Kardiyoloji

YÖKSİS Yazar Kaydı

Yazar Adı EVRANOS BANU,KOÇYİĞİT DUYGU,Gurses Kadri Murat,YALÇIN MUHAMMED ULVİ,ŞAHİNER MEHMET LEVENT,KAYA ERGÜN BARIŞ,ÖZER NECLA,AYTEMİR KUDRET
YÖKSİS ID 2258380

Metrikler

Scopus Atıf 24
Havuz Atıfları 0
Teşvik Puanı 12,60
Yazar Sayısı 8